Indoor Unit Installation Drawings

A
Mounting plate
B
Mounting plate fixing screw
3/16" × 1" (M4 × 25mm)
Front panel
1-15/16" (50mm)
or more from walls
(on both sides)
Air filters
C
Titanium apatite photocatalytic
air-purifying filter (2)
Filter frame
Tab
4
Room Air Conditioners J-Series
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
1-3/16" (30mm) or more
from ceiling
3/16" × 5/8"
(M4 × 16mm)
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
Air filter
3) Pull down.
Titanium apatite
photocatalytic
air-purifying filter
How to attach the indoor unit
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
Front grille
release, remove the front grille.
Caulk
pipe hole
gap
with putty.
Service lid
D
Wireless
remote
controller
F
Fixing screw for remote
controller holder
1/8" × 13/16" (M3 × 20mm)
Installation Manual
A
Mounting
plate
Clip
Bottom frame
Mark (rear side)
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe's cut line.
Wrap the insulation pipe with
the finishing tape from bottom
to top.
Before screwing the remote
controller holder to the wall,
make sure that control
signals are properly
received by indoor unit.
E
Remote
controller holder
27