4. Dimensions

4.1

Indoor Units

FTKS09/12JEVJU
THE MARK (→) SHOWS PIPING DIRECTION
REAR
30-5/16(770mm)
LEFT
FRONT PANEL FIXING SCREWS
BOTTOM
FLAPS
SIGNAL TRANSMITTER
2-5/16(58mm)
11/16(18mm)
WIRELESS REMOTE CONTROLLER
(ARC452A14)
FTXS09/12JEVJU
THE MARK (→) SHOWS PIPING DIRECTION
REAR
30-5/16(770mm)
LEFT
FRONT PANEL FIXING SCREWS
BOTTOM
FLAPS
SIGNAL TRANSMITTER
2-5/16(58mm)
11/16(18mm)
WIRELESS REMOTE CONTROLLER
(ARC452A12)
Room Air Conditioners J-Series
RIGHT
(INSIDE)
SIGNAL RECEIVER
OPERATION LAMP
TIMER LAMP
O O
N
FF
INDOOR UNIT ON/OFF SWITCH
ROOM TEMP. THERMISTOR
(INSIDE)
O O
N
FF
MODEL NAME
PLATE
BLADE ANGLE
UP/DOWN (AUTOMATIC)
COOLING
DRY
45˚
45˚
RIGHT/LEFT (MANUAL)
RIGHT
(INSIDE)
SIGNAL RECEIVER
OPERATION LAMP
TIMER LAMP
N
O O
FF
INDOOR UNIT ON/OFF SWITCH
ROOM TEMP. THERMISTOR
(INSIDE)
O O
N
FF
MODEL NAME
PLATE
BLADE ANGLE
UP/DOWN (AUTOMATIC)
COOLING
HEATING
15˚
45˚
45˚
FAN
RIGHT/LEFT (MANUAL)
45˚
INCLUDING
MOUNTING PLATE
7-7/8(200mm)
1-15/16(50mm)MIN.
7-51/64(198mm)
(SPACE FOR
MAINTENANCE)
GENERAL RATING
NAME PLATE
TERMINAL BLOCK
WITH EARTH
TERMINAL
(INSIDE)
GAS PIPE φ 3/8( φ 9.5mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT : ABOUT 15-23/64(390mm))
LIQUID PIPE φ 1/4( φ 6.4mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT : ABOUT 17-21/64(440mm))
FAN
45˚
2-9/64(54.5mm)
WALL HOLE FOR EMBEDDED PIPING
φ 2-9/16( φ 65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
INCLUDING
MOUNTING PLATE
7-7/8(200mm)
1-15/16(50mm)MIN.
7-51/64(198mm)
(SPACE FOR
MAINTENANCE)
GENERAL RATING
NAME PLATE
TERMINAL BLOCK
WITH EARTH
TERMINAL
(INSIDE)
GAS PIPE φ 3/8( φ 9.5mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT : ABOUT 15-23/64(390mm))
LIQUID PIPE φ 1/4( φ 6.4mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT : ABOUT 17-21/64(440mm))
DRY
45˚
2-9/64(54.5mm)
WALL HOLE FOR EMBEDDED PIPING
φ 2-9/16( φ 65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
Dimensions
AIRFLOW (INDOOR)
1-15/16(50mm)MIN.
(SPACE FOR
REQUIRED SPACE
MAINTENANCE)
DRAIN HOSE
(CONNECTING PART
φ 9/16( φ 14mm)
I.D.
φ 5/8( φ 16mm)
O.D.
THE HOSE LENGTH OF OUTSIDE
THE UNIT IS ABOUT 17-23/32(450mm))
30-5/16(770mm)
21-39/64(549mm)
3-31/32(101mm)
2-1/8(54mm)
WALL HOLE
φ 2-9/16( φ 65mm) HOLE
3D065952B
AIRFLOW (INDOOR)
1-15/16(50mm)MIN.
(SPACE FOR
REQUIRED SPACE
MAINTENANCE)
DRAIN HOSE
(CONNECTING PART
φ 9/16( φ 14mm)
I.D.
φ 5/8( φ 16mm)
O.D.
THE HOSE LENGTH OF OUTSIDE
THE UNIT IS ABOUT 17-23/32(450mm))
30-5/16(770mm)
21-39/64(549mm)
3-31/32(101mm)
2-1/8(54mm)
WALL HOLE
φ 2-9/16( φ 65mm) HOLE
3D065951B