Dell PowerEdge C6145 Hardware Owner's Manual page 100

Hide thumbs Also See for PowerEdge C6145:
Table of Contents

Advertisement

Table 2-2. The IPMI Command Table
IPMI Command
ipmitool raw 0x34 0xB1
<Byte1:4>
Byte 1 - Power
Management Enable(01h
enable)
Byte 2 - Power Capping
Enable(01h enable)
Byte 3 - Current Chassis
Power Capping Value(Low
Byte)
Byte 4 - Current Chassis
Power Capping
Value(High Byte)
ipmitool raw 0xc 1 1 3 <IP
Address>
ipmitool raw 0xc 1 1 6
<Subnet Mask>
ipmitool raw 0xc 1 1 12
<IP Address>
ipmitool raw 0x30 1
Return: ID
ipmitool raw 0x30 3 ID
0x11 0x2 0 0 0 1 <Delay
Mode>
ipmitool raw 0x30 1
100
|
Using the System Setup Program
Setup Option
SET POWER
MANAGEMENT
BEHAVIOR
IP Address
Subnet Mask
GateWay Address
Power Staggering
AC Recovery
Minimum Power
Description
The setting controls PSU Power, its
range limited in 450˜2000 W. The
value is sent to BMC by IPMI
command and BMC will control
PSU power. This setting can be seen
when
"Power
Management"
selected to "APML " mode and the
system board at location 2 in the
chassis.
Use this option to input BMC LAN
port IP address.
Use this option to input BMC LAN
port subnet mask address.
Use this option to input BMC LAN
port Gateway address.
Configures power recovery behavior.
This item can be seen when
"Remote on AC Power Loss" is
selected in "Power On" or "Last
State".
This parameter is only effective if
the Power Policy is not set to always
off.
0x00: Immediate Power On (No
Delay) : Default
0x01: Auto (Random), the auto
generated delay time must be in the
range of Minimum Power On Delay
and Maximum Power On Delay.
0x02:
User
Defined,
defined delay time must be in the
range of Minimum Power On Delay
and Maximum Power On Delay.
Configures time for power on delay,
is
the
user

Advertisement

Table of Contents
loading

Table of Contents