Trane INTELLIPAK Installation Operation & Maintenance page 5

Commercial single-zone rooftop air conditioners with cv or vav controls
Table of Contents

Advertisement

Sample Model No.: S X H G - D 1 1 4 0 A H 7 C G 8 D 1 0 0 1 AT,etc
Digit No.:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21+
Digit 1 - Unit Type
S = Self-Contained
Digit 2 - Unit Function(s)
E = DX Cooling, Electric Heat
F = DX Cooling, Natural Gas Heat
L = DX Cooling, Hot Water Heat
S = DX Cooling, Steam Heat
X = DX Cooling, Extended Casings
Digit 3 - Unit Airflow
H = Single-Zone
Digit 4 - Development Sequence
G = Seventh
Digits 5, 6, 7 - Nominal Capacity
C90 = 90 Tons
D11 = 105 Tons
D12 = 115 Tons
D13 = 130 Tons
Digit 8 Power Supply
4 = 460/60/3 XL
5 = 575/60/3 XL
E = 200/60/3 XL
F = 230/60/3 XL
Digit 9 - Heating Capacity
0 = No Heat
H = High Heat - 2 Stage
J = Limited Modulating High Heat
P = Full Modulating High Heat
Note: When the second digit calls
for "E" (electric heat), the following
values apply in the ninth digit:
W=190 kw
Note: When the second digit calls for
"L" or "S", one of the following valve
size values must be in Digit 9:
High Heat Coil: 3 = 1.0", 4 = 1.25",
5 = 1.50", 6 = 2.0", 7 = 2.5"
Low Heat Coil: C = 1.0", D = 1.25",
E = 1.50", F = 2.0", G = 2.5"
Digit 10 - Design Sequence
2
Note: Sequence may be any letter
A thru Z, or any digit 1 thru 9.
Digit 11 - Exhaust Option
O = None
7 = 100%, 15 HP w/ Statitrac
8 = 100%, 20 HP w/ Statitrac
9 = 100%, 25 HP w/ Statitrac
F = 50%, 15 HP
H = 100%, 30 HP w/ Statitrac
J = 100%, 40 HP w/ Statitrac
K = 100%, 15 HP w/o Statitrac (CV Only)
L = 100%, 20 HP w/o Statitrac (CV Only)
Digit 12 - Exhaust Air Fan Drive
0 = None
5 = 500 RPM
6 = 600 RPM
7 = 700 RPM
8 = 800 RPM
Digit 13 - Filter
A = Throwaway
C = High-Efficiency Throwaway
D = Bag with Prefilter
E = Cartridge with Prefilter
F = Throwaway Filter Rack Less Filter
Media
G = Bag Filter Rack Less Filter Media
Digit 14 - Supply Air Fan HP
C = 30 HP (2-15 HP)
D = 40 HP (2-20 HP)
E = 50 HP (2-25 HP)
F = 60 HP (2-30 HP)
G = 80 HP (2-40 HP)
Digit 15 - Supply Air Fan Drive
A = 1000 RPM
B = 1100 RPM
C = 1200 RPM
D = 1300 RPM
E = 1400 RPM
F = 1500 RPM
G = 1600 RPM
Digit 16 - Fresh Air
D = 0-100% Economizer (Std.)
Digit 17 - System Control
1 = Constand Volume Control
2 = VAV Supply Air Temperature
Control without Inlet Guide Vanes
3 = VAV - Supply Air Temperature
Control with Inlet Guide Vanes
4 = Space Pressure Control with
Exhaust VFD w/o Bypass
5 = Space Pressure Control with
Exhaust and Bypass
6 = VAV Supply Air Temperature Control 35 0 = None
with VFD without Bypass
7 = VAV Supply Air Temperature Control
with VFD and Bypass
8 = Supply and Exhaust Fan with
VFD and without Bypass
9 = Supply and Exhaust Fan with
VFD and Bypass
Echelon, LON, LONWORKS, LonBuilder, NodeBuilder, LonManager, LonTalk,
LonUsers, Neuron, 3120, 3150, the Echelon logo, and the LonUsers logo are
trademarks of Echelon Corporation registered in the United States and other
countries. LonLink, LonResponse, LonSupport, LonMaker, and LonPoint are
trademarks of Echelon Corporation.
5
Digit 18 - Accessory Panel
0 = None
A = BAYSENS008*
B = BAYSENS010*
C = BAYSENS013*
D = BAYSENS014*
E = BAYSENS019*
F = BAYSENS020*
G = BAYSENS021*
Digit 19 - Ambient Control
0 = Standard
Digit 20 - Agency Approval
0 = None (UL Gas Heater See Note 1)
1 = UL
2 = CSA
Note: Includes UL classified gas
heating section only when second
digit of Model No. is a "F".
Digits 21 - 36 - Miscellaneous
21 A = Unit Disconnect Switch
22 B = Hot Gas Bypass
23 C = Economizer Control
with Comparative Enthalpy
23 Z = Economizer Control
with Reference Enthalpy
23 W = Economizer Control w/Dry Bulb
23 0 = None W/O Economizer
24 E = Low-Leak Fresh Air Dampers
25 F = High Duct Temperature Thermostat
26 G = High Capacity Evaporator Coil (90-105 Ton Only)
H = Hi Cap Evap Coil & Hi Eff Cond Coil (90 Ton Only)
27 K = Generic BAS Module
28 L = High Efficiency Motors
(Supply and Exhaust)
29 M = Remote Human Interface
30 N = Ventilation Override Module
31 R = Extended Grease Lines
32 T = Access Doors
33 V = Inter-processor Communication
Bridge
34 0 = No communication module
34 Y = Trane Communication Interface Module
34 7 = LonTalk® Communication Interface Module
36 6 = Factory-Powered 15A GFI
Convenience Outlet