Install The Power Supply And The Media Converter Switch - Axis Q6042-S PTZ Installation Manual

Q60-s series dome network camera
Hide thumbs Also See for Q6042-S PTZ:
Table of Contents

Advertisement

3. Attach the dome cover to the top cover and tighten the screws (torque 3.2 Nm).
NOTICE
NOTICE
NOTICE
To prevent corruption of recordings, the SD card should be unmounted before it is ejected.
To unmount, go to Setup > System Options > Storage > SD Card and click Unmount.
Pressurize the Camera (Optional)
The camera housing can be filled with Nitrogen gas to prevent condensation.
Note
The camera housing has an outlet valve that limits the filling pressure to 0.5 bar (7 psi).
During normal use the pressure inside the camera housing may drop below that pressure.
For full protection make sure that the pressure is above 0.2 bar (3 psi) .
1. Set the regulator gauge on the gas cylinder to 0.5 bar (7 psi).
2. Remove the caps from the intake and outlet valve.
3. Place the chuck on the intake valve and press down to fill the camera with nitrogen.
4. When the pressure inside the camera housing reaches 0.5 bar (7 psi) the outlet valve will
open. Place your hand over the outlet valve to verify that the gas is flowing out.
5. Keep the gas flowing through the camera housing for one minute before removing the
chuck from the intake valve.
6. Lift the outlet valve to let the overpressure out of the camera unit.
7. Repeat the filling process a total of 3 times, leaving the the camera pressurized the
last time.
8. Put the caps back on the intake and outlet valves.

Install the Power Supply and the Media Converter Switch

The supplied media converter switch enables the multi-connector cable to send power from the
power supply (sold separately) and to send and receive data to and from external alarm devices
and the network.
20
AXIS Q60-S Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

S q6044-s ptzQ6045-s ptz

Table of Contents