Outdoor Units - Daikin CTXS09GVJU Service Manual

Super multi nx g-series
Hide thumbs Also See for CTXS09GVJU:
Table of Contents

Advertisement

Specifications
1.2

Outdoor Units

Model
Capacity
Power Consumption
Running Current
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant Oil
Charge
Type
Refrigerant
Charge
m³/min
Air Flow Rate
cfm
Type
Fan
Motor Output
Starting Current
Dimension (H×W×D)
Packaged Dimension (H×W×D)
Weight
Gross Weight
Operation Sound
(Sound Pressure)
Liquid
Piping Connection
Gas
Drain
Heat Insulation
No. of Wiring Connection
Max. Piping Length
Amount of Additional Charge
Max. Installation Height Difference
Drawing No.
Note:
1. The data are based on the conditions shown in the table below.
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
10
kW
W
A
W
oz
Lbs
H
M
L
H
M
L
W
A
inch (mm)
inch (mm)
Lbs (kg)
Lbs (kg)
dBA
inch (mm)
inch (mm)
inch (mm)
ft (m)
oz/ft (gram/m)
ft (m)
Cooling
Heating
Indoor ; 70°FDB/60°FWB
Outdoor ; 47°FDB/43°FWB
2MXS18GVJU
Cooling
Ivory White
Hermetically Sealed Swing Type
2YC45EXD
1,380
FVC50K
26.5
R-410A
5.73
49
43
1,730
1,518
Propeller
53
10.6
28-15/16 × 32-1/2 × 11-13/16" (736 x 825.5 x 300 mm)
15-3/8 × 31-7/16 × 39-5/16" (390.5 x 951 x 999 mm)
139 lbs (63 kg)
144 lbs (65 kg)
50
φ 1/4" (6.4 mm)× 2
φ 3/8" (9.5 mm) × 2
φ11/16" (17.4 mm)
Both Liquid & Gas Pipes
3 for Power Supply, 4 for Interunit Wiring
164' (50 m) (for Total of Each Room)
82' (25 m) (for One Room)
0.22 oz / 6.2 grams (98.4 ft/ 30 m or more)
49.2 ft (15 m) (between Indoor Unit and Outdoor Unit)
24.6 ft (7.5 m) (between Indoor Units)
3D058840
Piping Length
25 ft (7.5 m)
SiUS12-814
60Hz 208-230V
Heating
41
39
1,448
1,377
51
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents