4.7 INTERFACE MODE (Cont'd)
Menu
TG3 Series Service Manual
INTERFACE MODE
This screen shows the connection setting of input device (Keypad).
ENABLE : If the input device is connected, print data from the device will be
valid. If the device is disconnected, print data received from the PC
will be valid.
* The data received from the PC becomes invalid while the input
device is connected.
DISABLE : Only the print data received from the PC becomes valid.
* The data received from the input device becomes invalid.
The initial cursor position is at ENABLE.
Connection status of input device can be checked by the status icon displayed
in the Normal Mode.
Note : Changed settings will be in effect from the next power on.
This is a confirmation screen for setting the connected interface board configu-
rations.
If YES, it goes to the communication setting of the installed interface board.
If NO, it goes to IGNORE CR/LF screen.
The initial cursor position is at NO.
This setting determines whether Carriage Return and Line Feed codes are pro-
cessed or ignored. It only appears when an IEEE1284 interface is installed,
and the Protocol option is set to STATUS4, for Receive Buffer in multi buffer
mode.
Select YES to ignore the codes, and NO to process them.
This setting determines whether the CANCEL and DATA LINK ESCAPE codes
are processed or ignored. It only appears when the communication protocol
option is set to STATUS4.
Select YES to ignore the codes, and NO to process them.