8-2.

Typical Control Settings

NOTE
Material thickness determines weld
parameters.
Wire
Size
0.023 in
0.030 in
0.035 in
These settings are guidelines only. Material and wire type, joint design, fitup,
position, etc. affect settings. Test welds to be sure they comply to specifications.
Wire Size
.035 in
0.023 in
0.030 in
0.035 in
Recommendation
3.5 in per ampere
3.5 x 125 A = 437 ipm
2 in per ampere
1.6 in per ampere
1.6 x 125 A = 200 ipm
Low voltage: wire stubs into work
High voltage: arc is unstable (spatter)
Set voltage midway between high/low voltage
Metal thickness select will control
both voltage and wire feed speed by
selecting metal thickness.
1/8 or 0.125 in
Amperage Range
30 − 90 A
40 − 145 A
50 − 180 A
Wire Speed
(Approx.)
2 x 125 A = 250 ipm
Convert Material
Thickness to
Amperage (A)
(0.001 in = 1 ampere)
0.125 in = 125 A
Select Wire Size
Select Wire Speed
(Amperage)
125 A based on 1/8 in
material thickness
ipm = inches per minute
Select Voltage
Ref. 804 121-C
OM-923 Page 27