Hardware Monitor Function

Item
Feature

Environment Requirements

Item
Temperature
Operating
Non-operating
Humidity
Operating
Non-operating
Vibration
Operating
Non-operating
Drop Test
Definition
Test Standard
Package Cross Weight
KGs
0~9.1
9.1~18.2
18.2~27.3
27.3~45.4
10 drops: one corner, three edges, six surfaces
Chapter 1
• Smart fan control system, Thermal Cruise and Speed Cruise support
• Six VID input pins for CPU Vcore identification
• Two thermal inputs from optionally remote thermistors or 2N3904
transistors or Pentium 4 thermal diode output
• Four external voltage detect inputs
• Three intrinsic voltage monitoring (typical for Vbat, +5VSB, +5CC)
• Two fan speed monitoring inputs
• Two fan speed control (DC analog output)
• WATCHDOG comparison of all monitored items
• Overheat indication output
• Issue SMI#, IRQ, OVT# to activate system protection
O
O
+5
C ~ +35
C
O
O
-20
C ~ +60
C (storage packed), -10
15% to 80% RH, non-condensing
10% to 90% RH, non-condensing at 40
5 ~ 500Hz, 2.20g RMS random, 10 minutes per axis in all three axes
5 ~ 500Hz, 1.09g RMS random, one hour per axis in all three axes
Drop Test
The protection ability of packing & cushion must be capable of
withstanding, with no physical or functional damage, mechanical impact
from height-specific drops.
Drop Height
lbs
CM
0~20
76
20~40
61
40~60
46
60~100
31
Description
Specification
O
O
C ~ +60
C (unpacked)
o
C
Inch
30
24
18
12
Not of Drop
10
10
10
10
23