Fireplace installation

Install the fireplace assembly into the mantel (refer to mantel assembly
instructions).
!
NOTe 1: A 15 Amp, 120 Volt circuit is required. A dedicated circuit
is preferred but not essential in all cases. A dedicated circuit will be
required if after installation the circuit breaker trips or fuse blows on
a regular basis when the heater is operating. Additional appliances
on the same circuit may exceed the current rating of the circuit
breaker.
!
iMPORTANT: If not
using a Dimplex mantel,
the fireplace must be
installed in an enclosure
with the following
MiNiMuM dimensions
(Figure 5).
New Wall
construction
1. Select a suitable
location that is not
susceptible to moisture
and is away from
drapes, furniture and high traffic.
2. Place the fireplace in the desired location to see how it will look in
the room.
3. Mark the desired location on the floor.
4. Use studs to frame an opening of 26 ¾ inch (679 mm) wide X
23 ⅛ inch (587 mm) high X 9 inch (229 mm) deep.
Option #1: The power cord can be run from behind the trim and
along the wall to an outlet near the fireplace.
Option #2: A new outlet can be installed inside the framing
construction.
Figure 5
9"
(229 mm)
9
23 ⅛"
(587 mm)
26 ¾"
(679 mm)