Authenticator Diagnostics

This table contains the diagnostic information regarding the operation of the Authenticator associated with each port. An
entry appears in this table for each port that supports the Authenticator function. To view the Authenticator Diagnostics,
click Monitoring > Port Access Control > Authenticator Diagnostics.
The user may select the desired time interval to update the statistics, between 1s and 60s, where "s" stands for seconds. The
default value is one second.
The following fields can be viewed:
Parameter
Port
EntersConnecting
EapLogOffsConnecting
EntersAuthenticating
SuccessAuthenticating
TimeoutsAuthenticating
FailAuthenticating
ReauthsAuthenticating
EapStartsAuthenticating
Figure 11- 24. Authenticator Diagnostics window
Description
The identification number assigned to the Port by the System in which the Port
resides.
Counts the number of times that the state machine transitions to the
CONNECTING state from any other state.
Counts the number of times that the state machine transitions from
CONNECTING to DISCONNECTED as a result of receiving an EAPOL-Logoff
message.
Counts the number of times that the state machine transitions from
CONNECTING to AUTHENTICATING, as a result of an EAP-Response/Identity
message being received from the Supplicant.
Counts the number of times that the state machine transitions from
AUTHENTICATING to AUTHENTICATED, as a result of the Backend
Authentication state machine indicating successful authentication of the
Supplicant (authSuccess = TRUE).
Counts the number of times that the state machine transitions from
AUTHENTICATING to ABORTING, as a result of the Backend Authentication
state machine indicating authentication timeout (authTimeout = TRUE).
Counts the number of times that the state machine transitions from
AUTHENTICATING to HELD, as a result of the Backend Authentication state
machine indicating authentication failure (authFail = TRUE).
Counts the number of times that the state machine transitions from
AUTHENTICATING to ABORTING, as a result of a reauthentication request
(reAuthenticate = TRUE).
Counts the number of times that the state machine transitions from
AUTHENTICATING to ABORTING, as a result of an EAPOL-Start message
157