ENTERING THE PROGRAM MODE #1
Turn OFF the power from the Control Panel by pressing
Press and HOLD
and press and RELEASE
Continue HOLDING
ENTER THE PROGRAM MODE #2
Turn OFF the power from the Control Panel by pressing
Press and HOLD
and press and RELEASE
Continue HOLDING
until
ENTER THE PROGRAM MODE #3
Turn OFF the power from the Control Panel by pressing
Press and HOLD
and press and RELEASE
Continue HOLDING
until
RELEASE.
NOTE:
NOTE:
NOTE: If Main Power is
NOTE:
NOTE:
turned OFF or Rear Toggle
Switch is switched to
STANDBY, the Warmer Quality Timer
must be re-programmed.
PROGRAM WARMERS
Unit must be ON at the control panel.
Turn OFF the warmer at the the Control Panel by pressing one of the warmer
switches:
2
PROGRAMMING ONLY REQUIRED IF FACTORY SETTINGS MUST BE CHANGED
Changing the ADS™ System Program
IMPORTANT – Before entering the program mode, allow the unit to reach brewing temperature, then press the BREW
button to dispense at least 12 ounces of water. This is to clear any air that may be trapped within the water lines.
NOTE: For ALL functions you must first enter the programming mode.
Brew Temperature – Factory Pre-Set to 200°F
Function to set brew temperature, 170° to 204°F. Brew temperature will be indicated by READY-TO-BREW light blinking.
.
.
until
starts blinking; RELEASE.
READY TO BREW
BREW VOLUME - Factory Preset to Brewer Requirements
BREW CYCLE COUNTER
.
.
STOPS blinking; RELEASE.
READY TO BREW
LOW TEMPERATURE BREW LOCKOUT (DELTA) – Factory Preset to Delta 3
.
.
stops blinking and remains on;
READY TO BREW
WARMERS
Adjusting the
Adjusting the
Adjusting the T T T T T empera
Adjusting the
Adjusting the
emperature
empera
empera
empera
ture
ture
ture
ture
ALPHA Warmers feature two temperature settings -- HIGH and LOW (unit must be ON at the control panel). From the Warmer ON position. Press and hold the warmer button
for five seconds and the temperature will be set to LOW. LOW temperature is indicated by the "dimming" of the warmer indicator light above the Warmer Button. An
additional press of the Warmer Button will turn the warmer OFF. To return the warmer to HIGH (warmer should be ON), press and hold the warmer button for five seconds then
warmer will come on in the HIGH setting.
When the system is turned off at the ON/OFF button, it will remember the last warmer setting. Additionally, the ALPHA automatically turns the brew warmer on when the
BREW button is pressed.
Quality T T T T T imer – F
Quality
Quality
Quality
Quality
imer – F
imer – Factor
imer – F
imer – F
actor
actor
actor
actory Set to DISABLED
y Set to DISABLED
y Set to DISABLED
y Set to DISABLED
y Set to DISABLED
ALPHA Systems feature a Quality Timer which will cause the warmer light to blink advising you coffee should be replaced. The Quality Timer can be set from DISABLED (zero)
to 50 minutes in 5 min intervals.
To set, follow these instructions:
(Indiator light OFF).
CONFIRM/RESET BREW TEMPERATURE - Factory Preset to 200º
ENTER THE PROGRAMMING MODE #1:
Press
for two seconds, then RELEASE.
will start blinking. Each blink equals 2º F, starting at 170º.
READY TO BREW
To change Temperature, press and HOLD
.
will start QUICK flashing. Each QUICK flash equals 2º F.
READY TO BREW
After reaching 204º, temperature starts over at 170º.
RELEASE
when the desired temperature is reached.
To set and exit, press
.
CHANGE BREW VOLUME
ENTER THE PROGRAMMING MODE #1
Press and HOLD
until hot water starts running from sprayhead; then RELEASE.
When desired volume is reached, press
To set and exit, press
.
TO ACCESS BREW CYCLE COUNTER
ENTER THE PROGRAMMING MODE #2:
will now start a pattern of LONG and SHORT blinks.
READY TO BREW
This pattern identifies the number of brew cycles. SHORT blinks indicate the brew number from one [1] to nine [9].
LONG blinks separate the 1's, 10's, 1,000's and 10,000's.
ENTER THE PROGRAMMING MODE #3
This mode will give you a choice of minimum brew temperatures.
Delta 1
Delta 1
Delta 1
Delta 1 allows you to brew within 5 degrees from set temperature. This provides for consistent brew
Delta 1
temperature and consistent water density. If Delta 1 is used, run one half decanter first, cancel and
discard water. Enter program mode #1 and change brew volume to 1/2" below collar of decanter (one
small finger width).
Delta 2 allows you to brew within 15 degrees from set temperature. If Delta 2 is used, run ½ of a decanter
Delta 2
Delta 2
Delta 2
Delta 2
first, cancel and discard water. Enter program mode #1 and change brew volume to 3/4" below collar
of decanter (between one and two small finger widths).
Delta 3
Delta 3
Delta 3
Delta 3
Delta 3 (this is factory setting) will allow you to brew at any temperature. Back to back brewing is only
possible in this mode. If Delta 3 is used, run one half decanter first, cancel and discard water.
Enter program mode #1 and change brew volume to 1" below collar of decanter (two small finger
widths). The brew cone must be empty without a filter. This will ensure proper operation at all brew
rates.
Press and HOLD
until
gives off one quic flash, then release
READY TO BREW
your blining light pattern.
By pressing and holding the
again, you add another blink.
WARMER QUALITY TIMER
To Determine Warmer Setting and Change Time for ALPHA Systems:
Press and HOLD
until the indicator light turns ON then OFF; release.
The light will start blinking. Count the blinks. Each blink = 5 minutes (maximum 50 minutes).
At the end of the cycle, press and HOLD
flashes (11 flashes is the DISABLED position).
When the desired time is reached, RELEASE
To set and exit, press
.
.
again to stop flow.
. You have now added a blink to
until the light begins quick flashing. The cycle will start over after 11
.

Advertisement