roubleshooting
Built-in heater ready light does not illuminate
Possible causes
1.
The power is not turned ON
2.
The portable spot cleaner is not attached completely
Reduced Spray or No Spray
Possible causes
1.
Formula & water tank may be empty
2.
Formula & water tank may not be seated completely
3.
Pump may have lost prime in portable spot cleaning mode
4.
The portable spot cleaner is not attached completely
5.
Solution filter may be clogged
DirtLifter
PowerBrush does not turn
Possible causes
1.
The portable spot cleaner is not attached completely
2.
The unit is in the upright position
3.
Circuit breaker on machine (if equipped) may have tripped
4.
The belt is off or broken
Loss of suction power
Possible causes
1.
Tanks may not be seated properly
2.
Nozzles may not be assembled properly
3.
The portable spot cleaner is not attached completely
4.
Dirty tank has picked up maximum amount of
dirty water and has reached full line
5.
Formula & water tank is empty
6.
Suction gate is open
Other maintenance or service not included in the manual should be
performed by an authorized service representative.
Thank you for selecting a BISSELL product.

Please do not return this product to the store.

16
w w w . b i s s e l l . c o m
Remedies
1. The power must be ON to activate the heater ready light
2. Make sure the portable spot cleaner is attached
Push down firmly to check
Remedies
1. Refill tank
2. Turn power OFF. Remove and reseat tank
3. Hold end of hose below water level in tank to prime
4. Push down firmly to check connection
5. Follow steps under cleaning filter on page 13
Remedies
1. Make sure the portable spot cleaner is attached.
Push down firmly to check
2. Brushes only rotate when unit is reclined using the
recline pedal
3. Turn the machine OFF and unplug from outlet. Check
to see if foreign object is caught in brush roll. Remove
object. Plug machine in to reset circuit breaker
4. Turn power OFF and unplug unit from outlet. Follow
instructions on pages 14 and 15
Remedies
1. Pick up both tanks and reseat them so it they fit snugly on
the unit
2. Unplug the unit. Check to make sure the "lip" of the
nozzle is securely hooked into the groove on bottom of
Tank (see page 10)
3. Make sure the portable spot cleaner is attached.
Push down firmly to check
4. Empty dirty tank
5. Check fluid levels in formula & water tank
6. Check to make sure the suction gate is closed. Follow
"Cleaning suction gate" instructions on page 13