Rack-Mount Installation - Bosch UML-19P-90 User Manual

19-inch lcd flat panel monitor
Hide thumbs Also See for UML-19P-90:
Table of Contents

Advertisement

12
en | Installing the Monitor
2.
Figure 5.2 Mounting the Device
5.2.3

Rack-mount Installation

To rack the UML-19P-90 using the RMK-08 mounting bracket, do the following:
NOTICE! Prior to installing the UML-19P-90 monitor to the RMK-08 rack mount bracket, four
i
(4) user supplied rack mount screws and clips are required.
1.
2.
Figure 5.3 RMK-08 Mounting Guide Bracket Installation
Reference #
1
2
F01U099396 | 1.0 | 2008.11
Mount the unit to the mounting device (not provided) using the four (4) mounting holes
on the rear panel. The square mounting hole patterns are standard on 100 mm (3.9 in.)
centers.
Use a Phillips head screw driver to remove the base of the monitor.
Align the two (2) supplied mounting guide brackets flush with the screw holes on the
back of the monitor. Screw the (4) supplied self-tapping screws into the non-threaded
holes (see Figure 5.3).
Description
Self-tapping Screw
Mounting Guide Bracket
User's Manual
UML -19P-90 LCD Monitor
Bosch Security Systems, Inc.