Download Print this page

Step 7: Final Wiring - Hunter CEILING FAN TYPE 2 Installation Instructions Manual

Hunter ceiling fan type 2
Hide thumbs Also See for CEILING FAN TYPE 2:

Advertisement

NOTE: Assembly Methods for
Installer's Choice Hanging System
Your new Hunter fan can be hung in (2) different manners, one
being as a low profile fan and also as a ball type hanging fan.
Thus, installer's choice. Customer should read Steps 6 through 8
and decide which style of mounting to use.
Step 6: Fan Assembly
Low Profile Fan
A.
The canopy has (4) holes in the bottom. The large center
hole fits over the adaptor on top of the fan. The (3) remaining
holes are for the canopy assembly screws.
Place the canopy on top of the fan and align the proper holes.
See Figure 6. Make certain you have located the hole pattern by
checking to see that the canopy sits flat on top of the fan without
a space between the bottom of the canopy and the top of the fan.
If a space is present, rotate the canopy slightly, eliminating
the space.
ADAPTOR
FAN ASSEMBLY
FIGURE 6
B.
Next, secure the canopy to the top of the fan using (3) #10-32
screws with lockwashers packaged with the fan. Make certain
the screws are tight. Failure to do so could result in the fan falling.
CAUTION: To ensure proper engagement of the canopy
assembly screws, the canopy must fit snug against the top of
the fan.
CAUTION: Do not lift motor by wires.
C.
Being careful not to scratch the canopy finish, hang the fan
from the hook in the ceiling plate using the round hole in the top
of the canopy. See Figures 6 and 6A.
GREEN
GROUND WIRE
CONNECTOR
CANOPY
FAN
FORM NO. 41201-01 1/95
SCREWS WITH
LOCKWASHERS AND
LOCTITE ON THREADS
CANOPY
ROUND HOLE
SCREW HEAD
SCREW HOLE
CEILING
PLATE
Figure 6A
Hanging Fan
CAUTION: Do not lift motor by wires.
A.
Insert pipe nipple through canopy and feed wires from top of
motor through pipe nipple. Screw pipe nipple into fan until tight
(at least 4-1/2 turns). The setscrew locking the pipe nipple to
motor must be tightened very securely. See Figure 6B. Failure to
tighten screw could result in fan falling.
6" MIN.
MOTOR
Before hanging the fan from the ceiling plate align and engage
the tab in the bottom of the canopy with the groove in the hanger
ball. See Figure 7.
B.
Being careful not to scratch the canopy finish, hang the fan
from the hook in the ceiling plate using the round hole in the top
of the canopy. See Figures 6 and 6A.
NOTE: For mounting fan on vaulted ceiling, there are (2) sets of
holes on the side. Locking tab in side must be in up position. Use
set of holes in ceiling plate that assures locking tab in canopy is
in the up position.

Step 7: Final Wiring

A.
Connect electrical supply leads to the leads from motor,
using approved connectors. Connect black electrical supply lead
to the black motor lead and the black with white stripe motor
HOOK
lead (see Note). Connect the white electrical supply lead to the
white motor lead. Connect the ground wire to the green leads
from the motor and ceiling plate. See Figure 6A.
- 3 -
LEAD WIRES
PIPE NIPPLE BALL
CANOPY
PIPE NIPPLE
PIPE NIPPLE SETSCREW
(TIGHTEN SECURELY)
Figure 6B
GROOVE IN
HANGER BALL
TAB IN BOTTOM OF CANOPY
Figure 7 Aligning Tab & Groove
©1998 HUNTER FAN CO.

Advertisement

loading