OPERATION RANGES
The table below indicates the temperature and humidity ranges the air conditioner can be operated within.
Refer to the table for efficient use.
OUTDOOR
MODE
TEMPERATURE
-5°C/23°F to 43°C/109°F
-5°C/23°F to 43°C/109°F
COOLING
-10°C/14°F to 43°C/109°F
-15°C/5°F to 43°C/109°F
-20°C/-4°F to 24°C/75°F
-5°C/23°F to 24°C/75°F
HEATING
-15°C/5°F to 24°C/75°F
-10°C/14°F to 24°C/75°F
-5°C/23°F to 43°C/109°F
-5°C/23°F to 43°C/109°F
DRYING
-10°C/14°F to 43°C/109°F
-15°C/5°F to 43°C/109°F
The standardized temperature for heating is 7˚C/45˚F. If the outdoor temperature drops to 0˚C/32˚F or
below, the heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C/90˚F (indoor temperature), it does not cool at its full
capacity.
Type
cassette
Model
DVM
AVMKH(C)
II/III
DVM PLUS
KH(C)EAM
BAC
BAC Inverter
KH
Free Joint Multi
MHFK
INDOOR
TEMPERATURE
HUMIDITY
18°C/64°F to 32°C/90°F
21°C/70°F to 32°C/90°F
18°C/64°F to 32°C/90°F
18°C/64°F to 32°C/90°F
27°C/81°F or less
15°C/59°F to 27°C/81°F
27°C/81°F or less
27°C/81°F or less
18°C/64°F to 32°C/90°F
21°C/70°F to 32°C/90°F
18°C/64°F to 32°C/90°F
18°C/64°F to 32°C/90°F
1 Way
Slim 1 Way
cassette
AVXCS
ND1
AVXC1
-
SHEAV
EAV
NS1HXEN
MHFS
INDOOR
DVM, DVM PLUS II/III, BAC Inverter
BAC, Free Joint Multi
80% or less
BAC Inverter(UH026/035EAV1, RC026/035DHXEN)
BAC Inverter(UH052/060/070EAV1, RC052/060/070DHXEN)
DVM PLUS II/III, BAC Inverter(UH052/060/070EAV1, RC052/060/070DHXEN)
BAC
-
Free Joi n t Mul t i , DVM, BAC Inverter(UH026/035EAV1, RC026/035DHXEN)
BAC Inverter
DVM, DVM PLUS II/III, Free Joint Multi, BAC Inverter
BAC
-
BAC Inverter(UH026/035EAV1, RC026/035DHXEN)
BAC Inverter(UH052/060/070EAV1, RC052/060/070DHXEN)
2 Way
cassette
AVMGH(C)
AVXC2
CH(C)EAM
GH(C)EAM
CH(C)EZM
-
-
REMARKS
4 Way
mini 4 Way
cassette
cassette
AVMCH(C)
-
AVMC4
AVXC4
AVXCM
ND4
NDM
-
CHEAV
THEAV
CHEAS
NSMHXEN
-
MHFM