Junction Box Installation; Installing Flame Control Solenoid (Natural Gas Only) - Heat & Glo CRESCENT II CRESCENT II Owner's Manual

Installation and operation
Table of Contents

Advertisement

D. Junction Box Installation
It is recommended to wire the unit from outside the ap-
pliance.
• Remove the junction box assembly located on the outer
shell - right side (see Figure 10.3).
• Cut the zip ties holding the adaptor on the junction box.
• Remove the junction box from the cover plate.
• Loosen two screws on the Romex connector, feed the
necessary wire through the connector and tighten the
screws.
• Make all necessary wire connections and reattach the
junction box to the cover plate and to the outer shell.
E. Installing Flame Control Solenoid (Natural Gas Only)
1. Remove the screw and knob from the variable regulator
and discard.
2. Unscrew the nut from the regulator and discard.
3. Remove the bag containing a washer and blue and red
plungers from the side of the fl ame control solenoid.
Discard the red plunger.
4. Place washer on fl ame control solenoid (see Figure
10.4).
GAS CONTROL
VALVE
WASHER
FLAME CONTROL
SOLENOID
Figure 10.4
Figure 10.3 Junction Box Detail
VARIABLE REGULATOR
VARIABLE
REGULATOR
VARIABLE
REGULATOR
Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09
5. Insert the blue (natural gas) plunger into the fl ame
control solenoid (see Figure 10.4).
6. Thread the fl ame control solenoid with correct plunger
into the thread hole in the variable regulator. Turn one to
two turns only. Do not tighten or damage may occur.
7. Connect orange wires from control box to the fl ame
control solenoid.
KNOB
SCREW
NUT
WASHER
SOLENOID
JAM NUT
PLUNGER
JUNCTION BOX
COVER
PLATE
ROMEX
NOTE: Do NOT wire
110 VAC to wall switch.
31