Electrical Information; Recommendation For Wire; Connecting To The Appliance; Intellifi Re Ignition System Wiring And 3 Function Circuit Board - Heat & Glo CRESCENT II CRESCENT II Owner's Manual

Installation and operation
Table of Contents

Advertisement

10
10

Electrical Information

A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the junc-
tion box for proper operation of the appliance (Intellifi re
ignition).
NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout
and may cause explosion.
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
• If using thermostat use one compatible with a millivolt
gas valve system.
• Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
• Use low resistance thermostat wire for wiring from ignition
system to the wall switch and thermostat.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
28
Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09
C. Intellifi re Ignition System Wiring and 3
Function Circuit Board
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.1.
This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
This appliance is equipped with a 3 function circuit board
which operates on 110 VAC and 12 VDC.
This appliance is supplied with a 3 volt AC transformer
and a 12 volt DC transformer, which requires the installa-
tion of the supplied junction box. It is highly recommend-
ed that the junction box be installed at this time to avoid
reconstruction.
Optional Remote Control Requirements
To attach remote receiver in series with 3 function wall
switch see wiring diagram (Figure 10.2).
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
WARNING
Shock hazard.
• Replace damaged wire with type 105º C rated
wire.
• Wire must have high temperature insulation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crescent ii

Table of Contents