Junction Box Installation; Wall Switch Installation For Fan (Optional) - Heat & Glo Indoor/Outdoor Gas Fireplace Twilight-II-B Owner's Manual

Installation and operation
Table of Contents

Advertisement

E. Junction Box Installation
If the box is being wired from the OUTSIDE of the
appliance:
• Install the Romex™ connector (not included with
appliance) in the side wrap.
• Loosen two screws on the Romex connector, feed
the necessary length of wire through the connector
and tighten the screws.
• Make all necessary wire connections.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box to
the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 9.4).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 9.5):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box to the
appliance using a minimum of 14-3 with ground wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• Add a 1/4 in. insulated female connector to the red (switch
leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector
(1/4 in. male) as shown.
Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. M • 11/08
HEAT SHIELD
BLK
WHT
BLK
WHT
Figure 9.4 Junction Box Detail
• Loosen the two screws on the Romex connector, feed the
necessary length of wire through the connector and tighten the
screws.
• Make all necessary wire connections to the receptacle and
assemble the receptacle and cover to the junction box.
Minimum 14-3 AWG
with Ground
Junction Box
Red
Figure 9.5 Junction Box Wired to Wall Switch or BC10
14/2WG
COPPER GROUND
ATTACHED TO GRN SCREW
WITH GRN WIRE
GREEN WIRE
INSIDE BOX
NOTE: Do NOT wire
110 VAC to wall switch.
Red
Black
Black
White
White
Green
Green
Switch Box
Knockout
Switch
Power
Supply
Wires
29