Service Test 01 - Software Revision; Service Test 02 - High Ambient Override - Maytag Built-in Refrigeration Manual

Built-in refrigeration
Table of Contents

Advertisement

From this point forward the up and down arrows are used to move forward or backwards
through the Service Tests. The Power Interrupt Button will activate the service test.
If the service mode starts at any location other than 00 00 it is an indication that the
Service Tests mode was not properly exited when last serviced.
Service Test 01 – Software Revision
This test will allow you to view the current software
version installed on the refrigerator. At the current time
there is no method to update the software in the field.
Pressing the Power Interrupt Button will display the current
software version.
This display would indicate software version 1.04.
Pressing the Power Interrupt Button will return you to the
previous screen.
Service Test 02 – High Ambient Override
This is not really a test but a system setting for special
operating conditions. By activating the High Ambient
override you will alter the temperature control
programming. This setting should only be used in cases of
high temperatures and high humidity.
Pressing the Power Interrupt Button will activate this setting. When activated the
WORKING lamp will illuminate. The working lamp will return to normal operation when
you exit the Service Tests Mode. Upon reentry and selecting Service Test 02 the lamp will
indicate whether the High Ambient Override is activated. Pressing the Power Interrupt
Button will deactivate the High Ambient Override.
65