User Interface (Controls) - Maytag Built-in Refrigeration Manual

Built-in refrigeration
Table of Contents

Advertisement

User Interface (Controls)

The control panel at the top of the fresh food section is constructed of touch sensitive
glass. These switches will not repeat if held. If the consumer touches the switch area,
contact must be broken to activate the switch again.
The unit power switch is a "soft" power switch. This switch will turn on the cooling
system, the displays, the remainder of the control functions and the dispenser system.
This control does not power down the Main Control board. Even in the "Off" mode from
use of this switch, the Main Control board is operating waiting for input from the control
board. If a complete power down is desired, switch the Power switch off in the equipment
compartment.
The Door Alarm will activate after ten minutes of the door switch not being held in the
door closed position. If the consumer is not interested in the door alarm monitoring the
status of the door, tapping the Door Alarm sense pad will turn off the door alarm. When
on, the Door Alarm touch pad will be illuminated. When deactivated the touch pad will
not be illuminated.
The up and down arrows either above and below the word FREEZER control the desired
freezer temperature. The up and down arrows above and below the word
REFRIGERATOR control the fresh food compartment temperature.
When the fresh food door is opened, the display will show the current cabinet
temperature for the respective compartments. The first time the UP or DOWN arrows are
touched, the display will show the current desired temperature or setpoint. Subsequent
taps on the arrow will either raise or lower the desired temperature.
The FILTER indicators will only illuminate if a filter is holding the Water Filter Switch
closed. When a filter is installed, the display will start with the WORKING icon
illuminated. As the time nears for filter replacement, the ORDER icon will illuminate.
When 416 gallons of water has been used or six months have elapsed (whichever comes
first) the REPLACE FILTER icon will illuminate.
To reset the filter monitor the filter must be replaced with the system operating. If the
main power is turned off during the filter change, the filter monitor will not be aware of
the filter change.
The POWER INTERRUPT icon will illuminate in the case of a power outage. After a
power outage, the temperature is recorded in the compartment as soon as power is
restored. This high temperature reading will alternate with the current temperature
reading in the display. This will let the customer know how warm it was inside of the
refrigerator. The customer can then make an educated decision as to whether the contents
of the unit should be discarded.
To reset the power monitor, tap the POWER INTERUPT icon.