Under normal operation the evaporator will defrost following every cooling cycle. Once the refrigerant
stops circulating, cooling also stops. The nominal temperature inside the unit ranges from 45°F at the
bottom to 60°F at the top, which is sufficiently high enough for any frost that has accumulated on the
evaporator to melt and run off.
If the thermostat is set low enough to allow temperatures inside the unit to range below 32°F (particu-
larly at the top) frost may not completely melt and run off between run cycles and periodic manual
defrosting may be necessary.
The ClearVue™ thermal-glass door of the KitchenAid wine cellar is reversible.
1. Remove the two (2) screws securing the bottom hinge to the door.
2. Remove the two (2) screws securing the top hinge to the door.
3. Remove the door from the unit.
4. Remove the three (3) screws securing the top hinge to the cabinet.
5. Invert the top hinge and install it on the bottom opposite side of the cabinet.
6. Remove the three (3) screws securing the bottom hinge to the cabinet.
7. Invert the bottom hiinge and intall it on the top opposite side of the cabinet.
8. Attach the top hinge to the door.
9. Attach the bottom hinge to the door.
10. Adjust the door to assure a proper seal to the cabinet. (See below)
The wine cellar door should always be squared to the cabinet to ensure a proper seal.
1. Loosen (do not remove) the three (3) screws in the door hinge plate at the top of the cabinet.
2. Align the door so that it is squared to the cabinet.
3. Tighten the three scews on the top hinge plate.