REFRIGERATION SYSTEM DIAGNOSIS GUIDE
SYSTEM
SUCTION
CONDITION
PRESSURE
NORMAL
Normal
OVER-
Higher than
CHARGE
normal
UNDER-
Lower than
normal
CHARGE
PARTIAL
Somewhat
RE-
lower than
STRICTION
normal-in
vacuum
COMPLETE
In deep
vacuum
RE-
STRICTION
NO GAS
0PSIG
to
25" vacuum

COMPRESSOR WINDING RESISTANCE

To measure start winding resistance, measure across the Common (C) and Start (S) pins.
To measure run winding resistance, meausre across the Common (C) and the Run (R) pins.
When measuring resistance between the Common (C), Start (S) or Run (R) pins to ground, meter
should read infinity. Any resistance indicates a shorted compressor.
Specifications:
Start Winding Resistance C to S:
Run Winding Resistance C to R:
Pin Configuation:
C = Common
R = Run
S = Start
COMP.
SUCTION
DIS-
LINE
CHARGE
Slightly
Very hot
below room
temp.
Very cold
Slightly
may frost
warm
heavily
to hot
Warm -
Hot
near room
temp.
Warm -
Very hot
near room
temp.
Room temp.
Room temp.
(cool)
(cool)
Room temp.
Cool to hot
(cool)
28 ohms
8 ohms
CON-
CAPILLARY
DENSER
TUBE
Very hot
Warm
Warm
Cool
Top pass
Warm
warm
Lower pass
cool (near
room temp)
due to liquid
Room temp.
Room temp.
(cool) or
colder
Room temp.
Room Temp.
(cool)
Room temp.
Room temp.
(cool)
C
S
Pin Configuation
8
EVAP.
WATTAGE
Cold
Normal
Cold
Higher than
normal
Extremely
Lower than
cold neat
normal
inlet - Outlet
below room
temp.
Extremely
Lower than
cold near
normal
inlet - Outlet
below room
temp
No refrigera-
Lower than
tion
normal
No refrigera-
Lower than
tion
normal
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents