Clearances - Heat & Glo Wood Burning Fireplace RH-36 Series Owner's Manual

Wood burning fireplace installation and operation
Hide thumbs Also See for Wood Burning Fireplace RH-36 Series:
Table of Contents

Advertisement

B. Clearances
WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specifi ed in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
Figure 6.2
Storm Collar
Roof Flashing
(attic)
(insulation)
2 in. (51 mm) min.
Ceiling Firestop
48 in.
1219 mm
0 in.
to floor
Clearances to Combustible Materials
Note: Chimney air kit is not shown, but is required in Canada.
Heat & Glo • RH-36/RH-42 • 4044-153 • Rev W • 11/08
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
Attic
Insulation
Shield
(ceiling)
Offset/Return (secured
with hanger straps)
(ceiling)
Must have 2 in. (51 mm)
minimum clearance
to header
0 in. to level
of standoffs
1/2 in. (13 mm) to back &
sides of appliance
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rh-42 series

Table of Contents