Heat & Glo RHW-485 Owner's Manual
Heat & Glo RHW-485 Owner's Manual

Heat & Glo RHW-485 Owner's Manual

Hearth and home technologies woodburning fireplace owner's manual rhw-485, rhw-485h

Advertisement

Quick Links

Models:
RHW-485, RHW-485H

Woodburning Fireplace

Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re. Overfi ring will void your
warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Installation and service of this fi replace should
be performed by qualifi ed personnel. Hearth &
Home Technologies suggests NFI certifi ed or
factory-trained professionals, or technicians
supervised by an NFI certified
professional.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Heat & Glo • RHW-485 • 33221 Rev O • 08/06
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot
during operation and cool down.
Keep children away.
CAREFULLY SUPERVISE children in same room
as fi replace.
Alert children and adults to hazards of high
temperatures.
Keep clothing, furniture, draperies and other
combustibles away.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
Do not install unvented gas logs.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo RHW-485

  • Page 1: Woodburning Fireplace

    Alert children and adults to hazards of high temperatures. • Keep clothing, furniture, draperies and other combustibles away. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Owner’s Manual Installation and Operation Leave this manual with party responsible for use and operation.
  • Page 2 IF INSTALLATION OR OPERATING INSTRUCTIONS ARE MISSING CONTACT: HEARTH & HOME TECHNOLOGIES INC., 1915 W. SAUNDERS ST., MT. PLEASANT, IA 52641. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Date purchased/installed: Location on fi replace: Dealer phone:...
  • Page 3: Table Of Contents

    F. Contact Information ......48 An arrow ( ) found in the text signifi es change in content. Heat & Glo • RHW-485 • 33221 Rev O • 08/06...
  • Page 4: Listing And Code Approvals

    Not intended for use as a primary heat source. This fi replace is tested and approved as a decorative fi re- place. It should not be factored as a primary heat source in residential heating calculations. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING...
  • Page 5: Getting Started

    Stack effect creates negative pressure in lower levels. Hearth & Home Technologies recommends the use of direct vent fi replaces in basements. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Asphyxiation Risk Negative pressure can cause spillage of combustion fumes and soot.
  • Page 6 Consider the fi replace location relative to fl oor and ceiling and attic joists. Location Recommended Windward Outside Air Intake Figure 2.1 Recommended Chimney Locations Recommended Recommended Location Location Marginal Location Multi-level Roofs Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Location Recommended Leeward...
  • Page 7: Typical Fireplace System

    Typical Fireplace System Termination cap Storm Collar Factory-built fireplace Protective metal hearth strip(s) Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Chimney penetrates roof preferably without affecting roof rafters Offset/Return (with hanger straps) Attic insulation shield may...
  • Page 8: Tools And Supplies Needed

    • Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefi t. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Fire Risk Explosion Risk Inspect fireplace and components for damage.
  • Page 9: Framing And Clearances

    1816 77-1/2 1346 1245 1969 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation/appearance may vary due to individual design preference. Hearth & Home Technologies reserves the right to alter its products.
  • Page 10: Clearances

    3/4 in. (19 mm) to side of appliance (except at nailing flanges where it is 1/2 in. [13 mm]) Clearances to Combustible Materials Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Attic Insulation Shield hanger straps Must have 2 in.
  • Page 11: Sidewalls/Surrounds

    Fireplace Outside Model # Opening Dimensions RHW-415 RHW-485 1067 Sidewalls and Surrounds Heat & Glo • RHW-485 • 33221 Rev O • 08/06 4 in. 9-3/4 in. (248 mm) 39 deg. 1067 1219 Note: Fireplace header cannot be positioned until after the fireplace assembly is in place.
  • Page 12: Construct The Chase

    • Maximum unsupported chimney above roof Note: A maximum of two pairs of offsets and returns may be used. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 All outside walls should be insulated. Chase Constructions 16.5 ft 16.5 ft...
  • Page 13: Installation Of Fireplace

    Blockage may cause combustion air starvation. Flexible Duct (not supplied) 2 Wire Ties Outside Air Collar Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Fire Risk Asphyxiation Risk Do not draw outside combustion air from: •...
  • Page 14 Attic space higher than 3 ft termination cap Factory-built fireplace Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Handle left - open Handle right - closed Figure 4.4 Locating the Outside Air Control Outlet placed below the...
  • Page 15: Secure The Fireplace

    2 in. (51 mm). Figure 4.5 2 in. (51 mm) Figure 4.6 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 1 in. (25 mm) overlap Position the Protective Metal Hearth Strips Top piece must overlap bottom piece Raised Platform 1 in.
  • Page 16: Chimney Assembly

    Trees, buildings, roof lines and wind conditions affect performance. • Chimney height may need adjustment if smoking or overdraft occurs. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Termination Cap Additional support for tall chimneys Storm Collar...
  • Page 17: Chimney Requirements

    Do NOT connect to any air distribution duct or 16-3/4 system. 22-3/4 34-3/4 46-3/4 1187 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 6 ft (1.83 m) max. unsupported chimney above roof 35 ft (10.7 m) max. straight unsupported chimney height 16.5 ft (5.03 m) min.
  • Page 18: Using Offsets/Returns

    1397 58-1/8 1476 63-1/4 1607 68-1/2 1740 73-3/4 1873 76-7/8 1953 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 1-1/4 in. (32 mm) Figure 5.3 Chimney Offset/ Example: Your “A” dimen- sion from Figure 5.3 is 14 1/2 in. (368 mm). Using Table 5.2 the dimension...
  • Page 19: Assemble The Chimney Sections

    Use same dimensional lumber as joists. Ceiling fi restop slows spread of fi re and reduces cold air infi ltration. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 ROOM ABOVE (non-insulated ceiling) bottom ATTIC ABOVE (insulated ceiling)
  • Page 20: Install The Attic Insulation Shield

    Insulation Figure 5.6 14-1/2 in. (368 mm) Insulation Figure 5.7 Optional Additional Support Figure 5.8 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Tabs 14-1/2 in. (368 mm) Attic 24 in. Insulation (610 mm) Shield Ceiling Firestop 10-1/2 in.
  • Page 21: Complete The Enclosure

    Chimney must extend 2 ft (.6 m) above any portion of the roof within 10 ft (3 m) of the chimney Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Gas, Wood or Fuel Oil Termination (minimum) to 18 in.
  • Page 22: Chase Top

    1-1/2 in. (38 mm). See Figure 6.6. Flashing Collar Top of Pipe Figure 6.6 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Fire Risk • The minimum overlap of cap to pipe MUST be met or chimney may separate from cap.
  • Page 23 (metal or masonry) Figure 6.10 Installing a European Copper Series Termination Cap Heat & Glo • RHW-485 • 33221 Rev O • 08/06 The last section of pipe must stop between the distances given below. 2 in. (51 mm) above top of the chase.
  • Page 24: Accessories

    4 in. (102 mm) from fireplace side. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Asphyxiation Risk • Damper must be locked open when gas logs installed.
  • Page 25: Finishing

    0.20 5-7/8 in. 0.08 14-5/8 in. 0.07-0.05 16-5/8 in. - 23-3/8 in. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 1 in. (25 mm) overlap Positioning the Protective Metal Hearth Strips WARNING Fire Risk • Hearth extensions must be installed exactly as specifi...
  • Page 26: Finishing Material

    14-3/8 in. (365 mm) 50 deg. Header Standoff Figure 8.5 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Fire Risk Do NOT obstruct air inlet or outlet grilles. Finishing materials must not interfere with: • Operation of louvers or doors •...
  • Page 27: Operating Instructions

    Open Outside Air Kit Control Open Close Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING HOT! DO NOT TOUCH. SEVERE BURNS MAY RESULT. CLOTHING IGNITION MAY RESULT. Glass and other surfaces are hot during operation and cool down.
  • Page 28: Outside Air

    Only Hearth & Home Technologies glass doors may be used. See Figure 9.2 for proper glass door opera- tion. Figure 9.2 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Fire Risk • Close fi rescreen when burning fi replace.
  • Page 29: Grate

    When combined with tar and other organic vapors from burning wood it will form creosote which condenses in the relatively cool fi replace and chimney. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Fire Risk •...
  • Page 30: Starting A Fire

    • Curing of high temperature paint. • Open windows for air circulation. Odors may be irritating to sensitive individuals. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 CAUTION WARNING Fire Risk Keep combustible materials, gasoline and other fl ammable vapors and liquids clear of fi...
  • Page 31: Troubleshooting

    The damper should be open. Unsealed can lights? Air register from furnace near fireplace? Outside air closed? Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Overhanging tree? Bird's nest or leaves in termination cap? Structural changes in...
  • Page 32: Diagnostics And Problem Solving

    Burn seasoned wood: covered on top, split and stacked for 9 months to 2 years. Explanation of decorative nature of fi replace; suggestion of approved fi replace insert. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Solutions Solutions...
  • Page 33 Check for need for glass doors. Check for need for balanced air make-up system or raising chimney. Have chimney cleaned. Wait until fi re completely out before closing damper. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Solutions Solutions Solutions...
  • Page 34: Maintenance And Servicing The Fireplace

    Top Cover Slip Section ST375 Square Round Termination Cap Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Fire Risk • Inspect fi replace refractory annually. Crumbling, deteriorated refractory can allow overheating of surrounding materials. 1. Remove the 4 screws.
  • Page 35: Maintenance Task List

    A chimney fi re can permanently damage your chimney sys- tem. Failure to replace damaged components and make proper repairs creates risk of fi re. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 WARNING Asphyxiation Risk Fire Risk Annual inspection by qualified technician recommended.
  • Page 36: Reference Materials

    (165 mm) 23-3/8 in. (594 mm) 8-1/8 in. (206 mm) 1067 1067 1219 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 41-1/4 in. Gas Knockout (1048 mm) (effective height) 37-3/4 in. Junction (959 mm) 7-1/2 in.
  • Page 37: Fireplace Components

    HX4 Hearth Extension 1/2 in. (13 mm) Bi-fold Glass Doors DM1736 DM1742 16 in. (406 mm) 20 in. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Perception Glass Doors DP1736 DP1742 Traditional Brick Pattern Refractory Herringbone Pattern Refractory...
  • Page 38: Chimney Components

    12 in. (305 mm) 4-3/4 in. (121 mm) 4 in. (102 mm) Effective Height Heat & Glo • RHW-485 • 33221 Rev O • 08/06 ID4 Insulated Duct 4 in. (102 mm) i 42 in. (1067 mm) UD4 Uninsulated Duct 4 in.
  • Page 39 10-1/2 in. (267 mm) 2 in. (51 mm) JB877 Chimney Joint Band 10-1/2 in. (267 mm) CB876 Chimney Joint Band Heat & Glo • RHW-485 • 33221 Rev O • 08/06 14-1/2 in. (368 mm) Ceiling Firestop Catalog # FS338 0-deg.
  • Page 40 15-5/8 in. (397 mm) Catalog # LDS33 LDS46 23-1/8 in. (587 mm) Catalog # Heat & Glo • RHW-485 • 33221 Rev O • 08/06 20 in. (508 mm) 17 in. (432 mm) 9-3/8 in. (238 mm) 9-1/4 in. (235 mm) TCT375 Terra Cotta Cap 72 in.
  • Page 41 CT3-King 16 in. (406 mm) 31-7/8 in. (810 mm) 18 in. (457 mm) CT3-Knight Heat & Glo • RHW-485 • 33221 Rev O • 08/06 18-1/4 in. (464 mm) 40-1/8 in. (1019 mm) 20 in. (508 mm) CT3-Queen 21 in.
  • Page 42: Woodburning Termination Cap

    28 1/4 27 X 27 with 27 X 27 with Radiation Shield Radiation Shield Heat & Glo • RHW-485 • 33221 Rev O • 08/06 TR11 / 11T TV TR11 / 11T (with TR-TVK installed) 32 X 32 with 26 X 26...
  • Page 43 This page intentionally left blank. Heat & Glo • RHW-485 • 33221 Rev O • 08/06...
  • Page 44: Service Parts

    D. Service Parts RHW-485 Service Parts Beginning Manufacturing Date: N/A Exploded Parts Diagram Ending Manufacturing Date: Active RHW-485 (Damper Control Handle) Traditional Brick Herringbone Brick Heat & Glo • RHW-485 • 33221 Rev O • 08/06...
  • Page 45 Installation Instructions and Owner’s Manual Exterior Touch-up Paint Herringbone Brick Refractory option available week 03/04. Service Parts Service Parts List RHW-485 Heat & Glo • RHW-485 • 33221 Rev O • 08/06 RHW-485 Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active RHW-485 RHW-485H Qty.
  • Page 46 This page intentionally left blank. Heat & Glo • RHW-485 • 33221 Rev O • 08/06...
  • Page 47: Limited Warranty

    HHT reserves the right to make changes at anytime, without notice, in design, material, specifications and prices and the right to discontinue styles and products. WARRANTY Hearth & Home Technologies Inc. 20802 Kensington Blvd., Lakeville, MN 55044. Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Feb 2006...
  • Page 48: Contact Information

    Heat & Glo • RHW-485 • 33221 Rev O • 08/06 Leave this manual with party responsible for use and operation.