Accessories; Gas Log/Lighter Provision; Wood Burning Inserts; Install Fan - Heatilator Wood Burning Fireplace A36CH Owner's Manual

Installation and operation wood burning fireplace
Hide thumbs Also See for Wood Burning Fireplace A36CH:
Table of Contents

Advertisement

12
12

Accessories

A. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk! Use with
solid wood fuel or decorative gas appliance only. Gas fi re
generates fumes.
DO NOT install unvented gas logs
Damper must be locked fully open when gas logs are
installed
A certifi ed gas log lighter or decorative gas log set can be
installed in this fi replace.
Maximum input is 100,000 BTU/hr.
Decorative gas appliance must be certifi ed to ANSI
Z21.60 "Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces".
Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1.
A gas log set must incorporate a gas shutoff.
Gas log set requires the damper to be locked fully
open.
A listed automatic damper system with safety interlock
may be used in this fi replace with only compatible,
listed gas log sets. See damper system manufacturer's
instructions.
Knockouts are provided on both sides of the fi replace
and in refractories for 1/2 in. (13 mm) iron pipe.
Seal refractory around pipe with fi replace mortar or a
high temperature, noncombustible sealant.
Firebox
Refractory
Seal with
fireplace mortar
or high temp
noncombustible
sealant
Gas Line
Repack
Insulation
Knockout
(102 mm)
Figure 12.1 Gas Line Installation
40
Outer Shell
of Fireplace
Maintain air clearance
to combustibles.
Combustible
Materials
1-1/2 in.
(38 mm)
air space
Gas Line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
4 in.
Heatilator • A36C & A42C • 28396 • Rev AG • 11/08
B. Wood Burning Inserts
WARNING! Risk of Fire! Improper installation of wood in-
serts may cause fi replace or chimney system to overheat.
If a wood burning insert is being installed in this fi replace,
Hearth & Home Technologies recommends full reline of
the chimney.
Cooling air openings at the top of the chimney must not
be obstructed in any manner.
Hearth & Home Technologies recommends securing the
reline at the top of the fl ue and using the cap certifi ed for
use with this fi replace system.
C. Install Fan
Optional.
Follow instructions included with fan kit.
WARNING! Risk of Electric Shock! DO NOT remove
grounding prong from plug or route cord under or in
front of appliance. Plug directly into a properly ground-
ed three-prong receptacle and route cord away from
appliance.

Advertisement

Table of Contents
loading

This manual is also suitable for:

A42cA36cA42ch

Table of Contents