E. Combustible Mantel
See Figure 11.11.
A combustible mantel may be positioned no
lower than 12 in. (305 mm) above the top of the
fi replace opening.
A combustible mantel may have a maximum
depth of 12 in. (305 mm).
Combustible trim and materials cannot be placed
within 6 in. (152 mm) of the fi replace opening
(top or sides).
Combustible materials projecting more than
1-1/2 in. (38 mm) shall not be placed within
12 in. (305 mm) from the top of the fi replace
opening.
Combustible trim must not cover the metal
surfaces of the fi replace.
Mantel clearance is in accordance with Section
7-3.3.3 of ANSI/NFPA211.
F. Sidewalls/Surrounds
Adjacent combustible sidewalls must be located
a minimum of 12 in. (305 mm) from the fi replace
opening.
Combustible or noncombustible mantel legs,
surrounds and stub walls may be constructed
per Figure 11.12.
FLUSH
FRONT
10 3/4 in.
[273 mm]
Figure 11.12 Mantel Leg or Wall Projections (acceptable on both sides of opening)
Grid represents 1 in. scale
12 in.
[305 mm]
Heatilator • A36C & A42C • 28396 • Rev AG • 11/08
Combustible Wall
2 x 4 stud wall
Standoffs
Seal joint with
noncombustible
sealant
Figure 11.11 Clearances to Mantels or other Combustibles above Fireplace
BRICK
FRONT
A
B
12 in.
[305 mm]
Model #
A36
A42
Combustible Decorative Facing
12 in./305 mm MAXIMUM
Noncombustible
Decorative Facing
12 in.305 mm MINIMUM
Measured from top of fireplace opening
4 in.
[102 mm]
9 3/4 in.
[248 mm]
A
Fireplace Opening
Outside Dimensions
in.
36
mm
914
in.
42
mm
1067
6 ft (1829 mm
MINIMUM
base of fireplace
to ceiling
B
42
1067
48
1219
39