Check Firebox Refractory; Inspect Grate; Glass Cleaning - Heatilator Wood Burning Fireplace A36CH Owner's Manual

Installation and operation wood burning fireplace
Hide thumbs Also See for Wood Burning Fireplace A36CH:
Table of Contents

Advertisement

C. Check Firebox Refractory
Frequency: After each ash removal
By: Homeowner
WARNING! Risk of Fire! Inspect fi replace refractory.
Crumbling, deteriorated refractory can allow overheating
of surrounding materials.
Expansion and contraction will cause minor cracking of
the refractory. This is normal. The refractory will require
periodic replacement depending on use.
The panels should be replaced if
Cracks exceed ¼ inch (6 mm) in width,
Metal is exposed behind the refractory,
Large pieces of refractory fall out.
D. Inspect Grate
Frequency: After each ash removal
By: Homeowner
Inspect grate for:
Warping or sagging 1-1/2 in. (38 mm) or more
Broken welds
Burn-through of grate bars
For safe operation, replace only with an approved grate
from Hearth & Homes Technologies Inc.
E. Glass Cleaning
Frequency: As desired
By: Homeowner
CAUTION! Handle glass assembly with care. Glass is
breakable.
Avoid striking, scratching or slamming glass
Avoid abrasive cleaners
DO NOT clean glass while it is hot
Clean glass with a non-abrasive commercially available
cleaner or ashes:
Light deposits
-
Use household glass cleaner
Heavy deposits
-
Use wood ash on damp cloth or,
-
Use commercial fi replace glass cleaner (consult with
your dealer)
12