C. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or fi nishing materials must not interfere with
air fl ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or fi nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the fi nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 13.16.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
FACING MATERIAL UP TO 1/2 IN. THICK
MAY BE COMBUSTIBLE - TOP AND SIDES
NON-COMBUSTIBLE
BOARD (INCLUDED)
1 IN.
1 IN.
0 IN.
HIGH TEMPERATURE (300º F / 149º C MIN.)
TOP & SIDE SEAL JOINT
Figure 13.16 Facing Materials
56
0 IN.
1 IN.
0 IN.
Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08
Note: There are 3 metal tabs holding the non-combustible
board in place for shipping. These tabs are to be cut off or bent
back before fi nishing around the appliance front.