Q. Chimney Fire
In the event of a chimney fire:
Have the chimney and adjacent structure inspected by
qualified professionals. Hearth & Home Technologies
recommends that NFI or CSIA certified professionals, or
technicians under the direction of certified professionals,
conduct a minimum of an NFPA 211 Level 2 inspection
of the chimney.
• Replace components of the chimney and fireplace as
specified by the professionals.
Ensure all joints are properly engaged and the chimney
is properly secured.
A chimney fire can permanently damage your chimney sys-
tem. Failure to replace damaged components and make
proper repairs creates risk of fire.
September 1, 2008
September 1, 2008
Heat & Glo • NorthStar EPA Fireplace • 480-1081C
R. Fire Safety
To provide reasonable fire safety, the following should be
given serious consideration:
1. Install at least one smoke detector on each floor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer's placement and installation instructions,
and be sure to maintain regularly.
2. A conveniently located Class A fire extinguisher to contend
with small fires resulting from burning embers.
.
A practiced evacuation plan, consisting of at least two
escape routes.
4. A plan to deal with a chimney fire as follows:
In the event of a chimney fire:
a. Notify fire department
b.
Prepare occupants for immediate evacuation.
c.
Close all openings into the stove.
d. While awaiting fire department, watch for ignition of
adjacent combustibles from overheated stove pipe,
hot embers or sparks from the chimney.