Flashing Collar
Top of Pipe
Figure 29.1 Installing a TR342 Round Telescoping Termination Cap
NOTE:
TR342/TR344: For less air restriction to flue
gases, use top vent kit listed in Section 12.
•
For installations utilizing an ST75 Square Termination
Cap the last chimney section must not be more than
4-1/2 in. (114 mm) below the chase top. See Figure
29.2.
Cap Standoff
1-1/2 in.
(8 mm) min.
overlap
Top of Pipe
Figure 29.2 Installing an ST375 Square Termination Cap
•
For installations utilizing a TS345/TS345P Square
Termination Cap, the uppermost chimney section must
not be more than in. (76 mm) below the chase top. See
Figure 29..
Flashing
Collar
1-1/2 in.
(38 mm)
Top of Pipe
min.
overlap
Figure 29.3 Installing a TS345/TS345P Square Termination Cap
September 1, 2008
September 1, 2008
Storm Collar
2 in. (51 mm) min.
14-1/2 in. (368mm) max.
1-1/2 in. (38 mm) min.
overlap
Flashing Collar
2 in. (51 mm) min.
4-1/2 in.
(114 mm)
max.
2 in.
(51 mm)
min.
3 in.
(76 mm)
max.
Heat & Glo • NorthStar EPA Fireplace • 480-1081C
•
For installations utilizing a Terra Cotta Cap the last chimney
section must be between 7 in. (178 mm) below the chase
top and 2 in. (51 mm) above. See Figure 29.4.
1-1/2 in. (38 mm)
min. overlap
{
Top of Pipe
Figure 29.4 Installing a TCT375 Terra Cotta Cap
•
For chase installations you can use a Round Termination
Cap, a Round Telescoping Termination Cap, a Square
Termination Cap, or a Terra Cotta Termination Cap.
•
For installations utilizing a European Copper Series
Termination Cap, See Figure 29.5.
•
Install termination caps following instructions provided
with them.
Cap Base
bracket (8)
screw (8)*
chimney top
chase
top
(metal or masonry)
SL pipe
inner flue
Figure 29.5 Installing a European Copper Series Termination Cap
(CT3-King shown)
The last section of pipe
must stop between the
distances given below.
2 in. (51 mm) above top
of the chase.
7 in. (178 mm) below top
of the chase.
(cap inner flue)
2 - 6 in.
(51-152 mm)
2 in. (51 mm)
typical
Page 29