B. Install Fireplace & Chimney
Install as per Sections 7 and 8.
C. Install Chase Top
You MUST use a chase top in a chase installation. Chase
tops are available from your Heatilator dealer or may be
fi eld constructed.
Include a turndown and drip edge to prevent water from
seeping into the chase.
Include a 2 in. (51 mm) soldered, welded or spun collar
around pipe opening to keep water out.
Provide a 1/8 in. (3 mm) gap around the fl ue pipe.
Slope the chase top downward away from the
opening.
WARNING! Risk of Fire! DO NOT caulk the pipe to the
chase top collar.
Caulk all seams to prevent leaks.
Refer to Figure 9.3.
Heatilator • Multi-Sided Woodburning Fireplace • 34955 • Rev V • 11/08
Slope Downward
(1/4 in. per foot
minimum)
Figure 9.3
Chase Top Construction
2 in. (51 mm) Collar
on Chase Top
Turn-down
Drip Edge
Chase
.018 (26 ga) min.
Galvanized
Chase Top