Locating Fireplace & Chimney - Heatilator FL92 Owner's Manual

Multi-sided wood burning fireplace
Hide thumbs Also See for Heatilator FL92:
Table of Contents

Advertisement

E. Locating Fireplace & Chimney
Location of the fi replace and chimney will affect perfor-
mance.
Install within the warm airspace enclosed by the building
envelope. This helps to produce more draft, especially
during lighting and die-down of the fi re.
Penetrate the highest part of the roof. This minimizes
the effects of wind loading.
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
Minimize the use of chimney offsets.
Consider the fi replace location relative to fl oor and ceiling
and attic joists.
Take into consideration the termination requirements in
Section 8 and Section 9.
NOTICE: Locating the fi replace in a basement or in a location
of considerable air movement can cause intermittent smoke
spillage from fi replace. Do not locate fi replace near
frequently open doors
central heat outlets or returns
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Windward
Figure 5.2
Recommended Chimney Locations
16
Recommended Location:
• Above peak
Marginal Location:
• Below peak
Recommended:
• Insulated exterior chase
in cooler climates
Heatilator • Multi-Sided Woodburning Fireplace • 34955 • Rev V • 11/08
Recommended Location:
• Above peak
• Inside heated space
Marginal Location:
• Wind loading possible
Multi-level Roofs
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Leeward