Completing Grate Set-Up; Checking Pilot Plate - Heat & Glo 8000CF-OAK-IPI Owner's Manual

Installation and operation
Hide thumbs Also See for 8000CF-OAK-IPI:
Table of Contents

Advertisement

E. Completing Grate Set-up
1. Straighten the tabs on the grate bracket (see Figure
7.10) and remove grate from unit.
2. Remove grate bracket (see Figure 9.6) by bending it
back and forth until it breaks. Discard grate bracket.
3. Remove 4 tabs holding base refractory (see Figure
7.10) by bending tabs back and forth until they break.
4. Reinstall grate into unit (see Figure 9.7).
REMOVE GRATE
REMOVE GRATE BRACKET
REMOVE TAB HOLDING DOWN
BASE REFRACTORY (4 PLACES)
Figure 9.6 Removing Grate
RE-INSTALL
INTO THE UNIT
Figure 9.7 Re-install grate in unit
34
STRAIGHTEN TO
REMOVE GRATE
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08
F. Checking Pilot Plate
Note: Ensure pilot plate is in place. This will ensure pilot
stability (see Figure 9.8)
Figure 9.8
PILOT
PLATE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8000cflp-oakipi

Table of Contents