Heat & Glo 8000CF-OAK-IPI Owner's Manual page 22

Installation and operation
Hide thumbs Also See for 8000CF-OAK-IPI:
Table of Contents

Advertisement

C
V
B
J
V
V
i
D
V
= VENT TERMINAL
V
A
= 12 inches.................clearances above grade, veranda,
(See Note 1)
B
= 12 inches.................clearances to window or door
C
= 18 inches.................vertical clearance to unventilated
30 inches .................for vinyl clad soffi ts and below
D
= 9 inches..................clearance to outside corner
E
= 6 inches...................clearance to inside corner
F
= 3 ft. (Canada) ..........not to be installed above a gas
G
= 3 ft. ..........................clearance to gas service regulator
H
= 9 inches (U.S.A.)
12 inches (Canada) clearance to non-mechanical
(See Note 2)
i
= 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (pow-
(See Note 2)
** a vent shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the fl oor, or meets Note 2.
Note 1: On private property where termination is less than 7 feet above a
sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap
shield is suggested. (See vents components page)
Note 2: Termination in a covered alcove space (spaces open only on one
side and with an overhang) are permitted with the dimensions specifi ed
for vinyl or non-vinyl siding and soffi ts. 1. There must be 3 feet minimum
between termination caps. 2. All mechanical air intakes within 10 feet
of a termination cap must be a minimum of 3 feet below the termination
cap. 3. All gravity air intakes within 3 feet of a termination cap must be a
minimum of 1 foot below the termination cap.
Figure 6.4 Minimum Clearances for Termination
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
22
E
A
B
B
V
V
A
X
= AIR SUPPLY INLET
porch, deck or balcony
that may be opened, or to perma-
nently closed window. (Glass)
soffi t or to ventilated soffi t located
above the terminal
electrical service
meter/regulator assembly within 3
feet (90 cm) horizontally from the
center-line of the regulator
vent outlet
air supply inlet to building or the
combustion air inlet to any other
appliance
ered) air supply inlet
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08
F
U.S
(3 FT.)
M
G
V
X
H or i
= AREA WHERE TERMINAL IS NOT PERMITTED
J** = 7 ft. ......................... c l e a r a n c e a b o v e p a v e d
(See Note 1)
K
= 6 inches................. clearance from sides of electri-
(See Note 5)
L
= 12 inches................ clearance above electrical
(See Note 5)
Covered Alcove Applications
M*** = 18 inches .............clearance under veranda, porch,
42 inches ......... vinyl
N
= 6 inches ........... non-vinyl sidewalls
12 inches ......... vinyl sidewalls
O
= 18 inches ......... non-vinyl soffi t and overhang
42 inches ......... vinyl soffi t and overhang
P
= 8 ft.
1 cap
2 caps
3 caps
4 caps
Q
= # termination caps x 3
MIN
Note 3: Local codes or regulations may require different
clearances.
Note 4: Termination caps may be hot. Consider their proximity to
doors or other traffi c areas.
Note 5: Location of the vent termination must not interfere with
access to the electrical service.
In the U.S and Canada: Vent system termination is NOT permitted
in screened porches.
Vent system termination is permitted in porch areas with two or more
sides open. You must follow all side walls, overhang and ground
clearances as stated in the instructions.
Heat & Glo assumes no responsibility for the improper performance
of the appliance when the venting system does not meet these
requirements.
O
N
P
V
R
Q
(See Note 2)
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
sidewalk or a paved driveway
located on public property
cal service
service
deck, balcony or overhang
Q
R
MIN
3 feet
2 x Q
6 feet
1 x Q
9 feet
2/3 x Q
12 feet
1/2 x Q
R
= (2 / # termination caps) x Q
MAX
V
L
K
K
Electrical
V
Service
C
V
MAX
ACTUAL
ACTUAL
ACTUAL
ACTUAL
ACTUAL