Vent Information and Diagrams

A. Vent Guidelines
WARNING!
Fire Risk/Asphyxiation! This appliance requires
the specifi ed pipe for operation. Incorrect pipe may cause spill-
age, condensation and overheating.
These models require the following size B-vent double
wall, or single wall rigid or fl ex vent pipe.
Model
6000GBV
6000GBV-IPI
• Follow pipe manufacturer's installation guidelines when
installing the appliance.
WARNING!
Fire Risk/Explosion/Asphyxiation!
connect this gas appliance to a chimney fl ue serving a
separate solid-fuel or gas burning appliance.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
May impair safe operation of this appliance or other appli-
ances connected to the fl ue.
B. Vent System Confi guration
CAUTION! Risk of Fire! ALL vent confi guration specifi -
cations MUST be followed.
to these specifi cations. Appliance performance will suffer if
specifi cations are not followed.
Rise to Run Ratio = 2:1
Maximum Total Horizontal Run = 15 Feet
Minimum Total Vertical Rise = 9 Feet
Maximum Total Vertical Rise = 30 Feet
Maximum Number of Elbows: Two 90º or Four 45º
WARNING! Risk of Fire or Explosion!
er combustibles must not infringe on clearances.
• ALWAYS maintain specifi ed clearances around venting and
fi restop systems.
• Install fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe
may cause fi re.
Pipe Size
6 inch
6 inch
DO NOT
This product is tested and listed
Insulation and oth-
Heat & Glo • 6000GBV, 6000GBV-IPI • 2104-900 Rev. H • 11/08
9 FEET
MINIMUM
Figure 7.1
Note: Horizontal runs must have
minimum rise in accordance with
mechanical codes.
VENT SUPPORTS
ARE PER VENT
MANUFACTURER'S
SPECIFICATIONS.
MAXIMUM HORIZONTAL RUN IS 50%
OF VERTICAL. HORIZONTAL RUN
CANNOT BE MORE THAN 15 FT .
Figure 7.2
MINIMUM
VERTICAL
9 FEET
45 DEGREES
ELBOW
90 DEGREES
ELBOW
Figure 7.3
MINIMUM CLEARANCES
ARE PER VENT
MANUFACTURER'S
SPECIFICATIONS
METAL
PLUMBER'S
STRAP
VENT SUPPORTS ARE PER
VENT MANUFACTURER'S
SPECIFICATIONS
METAL
PLUMBERS' STRAP
MAXIMUM
HORIZONTAL
15 FEET
OFFSETS EXCEEDING
45 DEGREES ADAPT
HORIZONTAL LIMITATIONS
Note: Maximum horizontal
distance is 50% vertical vent
height.