E.
Junction Box Installation
If the box is being wired from the OUTSIDE of
the appliance:
• Remove the cover plate located on the outer
shell - right side (see Figure 10.3).
• Install the supplied
Romex™
cover plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and reat-
tach the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction
box/receptacle to the outer shell, rotate the
junction box inward to disengage it from the
outer shell (see Figure 10.3).
• Pull the electrical wires from outside the ap-
pliance through this opening into the valve
compartment.
F.
Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall
mounted switch for use with a fan (See
Figure 10.4):
• The power supply for the appliance
must be brought into a switch box.
• The power can then be supplied from
the switch box to the appliance using
a minimum of 14-3 with ground wire.
• At the switch box connect the black
(hot) wire and red (switch leg) wire to
the wall switch as shown.
• At the appliance connect the black
(hot), white (neutral) and green
(ground) wires to the junction box as
shown.
• Add a 1/4 inch insulated female con-
nector to the red (switch leg) wire,
route it through the knockout in the
face of the junction box, and connect
to the top fan switch connector (1/4
inch male) as shown.
30
connector in the
Figure 10.4 Junction Box Wired to Wall Switch
Hearth & Home Technologies • Bravo, Aztec • InD • 703-900 Rev. N • 8/06
Figure 10.3 Junction Box Detail
• Feed the necessary length of wire through the connector.
• Make all necessary wire connections to the junction box/re-
ceptacle and assemble the junction box/receptacle to the outer
shell.
MINIMUM 14-3 AWG
WITH GROUND

JUNCTION BOX

Red
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
NOTE: Do NOT wire
110VAC to wall switch.
Red
Black
White
Green
SWITCH BOX
SWITCH
Black
White
Green
POWER