  • Page 1 Owner’s Guide Installation Instructions Air Sourced 310 Heat Pump Water Heater This water heater must be installed and serviced by an authorised person. Please leave this guide with the householder.
  • Page 2 Rheem Australia Pty Ltd. TRADE MARKS ® Registered trademark of Rheem Australia Pty Ltd. ™ Trademark of Rheem Australia Pty Ltd. Note: Every care has been taken to ensure accuracy in preparation of this publication. No liability can be accepted for any consequences, which may arise as a result of its application.
  • Page 3: Table Of Contents

    CONTENTS HOUSEHOLDER – We recommend you read pages 4 to 13. The other pages are intended for the installer but may be of interest. About Your Water Heater ......................4 Regular Care ..........................8 Water Supplies..........................9 Save A Service Call ........................11 Installation ..........................
  • Page 4: About Your Water Heater

    The model you have chosen is a 551 series model. The 551 310 model heat pump water heater is recommended for connection to a minimum 16 hour per day power supply.
  • Page 5 If the electrical supply conduit to the water heater is damaged, it must be replaced by an authorised person in order to avoid a hazard. Phone your nearest Rheem Service Department or Accredited Service Agent to arrange for an inspection.
  • Page 6 Time of Use electricity supply due to a more expensive tariff rate applying. A timer will affect the operating times of both the heat pump circuit and the booster heating unit. Note: The 551 310 model heat pump water heater is recommended for connection to a minimum 16 hour per day power supply.
  • Page 7 At the end of the service life of the heat pump water heater and prior to the water heater being disposed of, a person qualified to work with refrigerants must recover the refrigerant from within the sealed system. The refrigerant must not be vented to atmosphere. Phone your nearest Rheem Service Department or Accredited Service Agent to arrange for an inspection.
  • Page 8: Regular Care

    If water does not flow freely from the drain line when the lever is lifted, then the water heater should be checked by your nearest Rheem Service Department or Accredited Service Agent. The temperature pressure relief valve should be checked for...
  • Page 9: Water Supplies

    WATER SUPPLIES This water heater must be installed in accordance with this advice to be covered by the warranty. This water heater is manufactured to suit the water conditions of most public reticulated water supplies. However, there are some known water chemistries which can have detrimental effects on the water heater and its operation and / or life expectancy.
  • Page 10 WATER SUPPLIES CAUTION If the water supply has a TDS greater than 150 mg/L and a green anode has not been changed to a black anode, or if the TDS is greater than 600 mg/L and the anode has not been changed to a blue anode, there is the possibility the anode may become overactive and hydrogen gas could accumulate in the top of the water heater during long periods of no use.
  • Page 11: Save A Service Call

    The water heater, during backup heating mode will heat the water to a temperature of 70°C. The boost capacity of the heating unit in backup heating mode is 110 litres. Phone your nearest Rheem Service Department or Accredited Service Agent to arrange for an inspection.
  • Page 12 70°C. The boost capacity of the heating unit in backup heating mode is 110 litres. Phone your nearest Rheem Service Department or Accredited Service Agent to arrange for an inspection.
  • Page 13 Heavy flows of hot water until the water heater is cold - then stops until water reheats The water heater must be switched off at the isolating switch or switchboard. Phone your nearest Rheem Service Department or Accredited Service Agent to arrange for an inspection. HIGHER THAN EXPECTED ELECTRICITY BILLS With the installation of your new air sourced heat pump water heater, maximum electrical energy savings can be achieved.
  • Page 14: Installation

    In New Zealand, the installation must conform with Clause G12 of the New Zealand Building Code. The 551 310 model heat pump water heater is recommended for connection to a minimum 16 hour per day power supply.
  • Page 15 INSTALLATION It is recommended the heat pump water heater be installed at ground or floor level and must stand vertically upright, supported by a level slab or solid base. The base of the water heater is made of corrosion resistant material, and it may be placed directly in contact with the supporting surface.
  • Page 16 INSTALLATION HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. It is necessary and we recommend that a temperature limiting device be fitted between the water heater and the hot water outlets in any ablution area such as a bathroom or ensuite, to reduce the risk of scalding. The installing plumber may have a legal obligation to ensure the installation of this water heater meets the delivery water temperature requirements of AS/NZS 3500.4 so that scalding water temperatures are not delivered to a bathroom, ensuite or other ablution area.
  • Page 17 INSTALLATION CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A 551 310 model heat pump water heater should not be installed as part of a circulated hot water flow and return system in a building. If a circulated flow and return system is required, it is necessary to bypass the heat pump water heater and install a secondary water heater connected to the hot water flow and return line and supplied from the heat pump water heater.
  • Page 18 INSTALLATION REDUCING HEAT LOSSES The cold water line to and the hot water line from the water heater must be insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed. ANODE TYPES The vitreous enamel lined cylinder of the water heater is only covered by warranty when the total dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is installed.
  • Page 19: Typical Installation

    INSTALLATION TYPICAL INSTALLATON – OUTDOOR LOCATION TYPICAL INSTALLATION HEAT PUMP WATER HEATER...
  • Page 20 DIMENSIONS AND TECHNICAL DATA HEAT PUMP DIMENSIONS System number 551 310 Part numbers Model Number 1.8 kW 551 310 04 Tank only 1.8 kW T551 310 04 2.4 kW 551 310 05 Tank only 2.4 kW T551 310 05 3.6 kW 551 310 07 Tank only 3.6 kW...
  • Page 21: Heat Pump And Tank Assembly

    HEAT PUMP AND TANK ASSEMBLY STORAGE TANK AND HEAT PUMP MODULE The heat pump water heater is made of two main components, the storage tank and the heat pump module. For transport and handling (weight) purposes both items are shipped separately and designed to be assembled at the installation site.
  • Page 22 HEAT PUMP AND TANK ASSEMBLY ASSEMBLY PROCEDURE Warning: The heat pump must be assembled, plumbed and filled with water prior to power being connected and switched on. The following procedure should be followed to properly lift, place and connect the heat pump module onto the storage tank: Storage Tank: Remove all packaging including the carton base from the storage tank and position in its intended location, supported by a level slab or solid base.
  • Page 23 HEAT PUMP AND TANK ASSEMBLY Air Louvre Removal: Using a Phillips head screw driver, remove the six (6) screws from each of the two air louvres (twelve (12) screws in total). Remove the louvres from the heat pump module.  Electrical Cover: Remove the mounting screw from the side of the electrical cover.
  • Page 24 HEAT PUMP AND TANK ASSEMBLY Heat Pump Module Placement: Using two people, one person on each lifting bar, lift the heat pump module and place it on the top of the storage tank. It is recommended to place the hands under the bar to enable the lift in a curl action. Ensure the two water fittings on the storage tank pass through the openings marked “INLET”...
  • Page 25 HEAT PUMP AND TANK ASSEMBLY Inlet Flexible Braided Hose: Attach the flexible braided hose marked “INLET” to the water fitting marked “INLET”. Tighten the swivel nut on the hose using a 24 mm spanner.  Push down the pipe seal ring to seat over the swivel nut and against the pipe seal cover. ...
  • Page 26 HEAT PUMP AND TANK ASSEMBLY Air Bleed Valve: Open the air bleed valve screw by rotating anticlockwise one turn. This will allow air to bleed from the circulator and flexible hose during the filling of the tank process. Leave the screw in this position. ...
  • Page 27 HEAT PUMP AND TANK ASSEMBLY Electrical Cover: Replace the electrical cover, engaging the bottom of the cover into the slots on the supporting bracket. Secure at the side with the mounting screw.  Water Connections: Connect the cold water supply and the hot water pipe work to the water heater. Connect the temperature pressure relief valve and its drain line.
  • Page 28: Connections - Plumbing

    CONNECTIONS – PLUMBING CONNECTION SIZES Hot water connection: RP¾/20. Cold water connection: RP¾/20. Relief valve connection: RP½/15.  All plumbing work must be carried out by a qualified person and in accordance with the Plumbing Standard AS/NZS 3500.4 and local authority requirements. ...
  • Page 29 CONNECTIONS – PLUMBING EXPANSION CONTROL VALVE Local regulations may make it mandatory to install an expansion control valve (ECV) in the cold water line to the water heater. In other areas, an ECV is required if the saturation index is greater than +0.4 (refer to “Water Supplies”...
  • Page 30: Connections - Electrical

    A secondary isolating switch may be installed within reach of the water heater. The 551 310 model heat pump water heater is recommended for connection to a minimum 16 hour per day power supply.
  • Page 31: Wiring Diagram

    CONNECTIONS – ELECTRICAL WIRING DIAGRAM RELAY ORANGE N.O. N.C. WHITE BLUE BLUE BLUE BLUE BLACK BLACK COMP BLACK BROWN BLUE TANK SENSOR CABLE THERMISTORS CONTROL BOARD ROBERTSHAW "ST" ADJUSTABLE THERMOSTAT SINGLE POLE, SINGLE THROW GREEN/YELLOW BLUE WHITE HEATING UNIT Electrical Circuit for Heat Pump – Robertshaw “ST” Thermostat...
  • Page 32: Multiple Installations

    MULTIPLE INSTALLATIONS A multiple installation of Rheem heat pump water heaters on a single manifold or multiple manifolds is ® possible, using the Equa-Flow manifold system, where large volumes of hot water is required. The Equa- Flow principle will function with water heaters in line, around a corner or in rows back to back...
  • Page 33 Model heater removal. Air flow through the heat pump must be parallel 310 HAV 1545 645 900 900 2445 900 900 300 1670 1675 to the adjacent heat pump water heater. MULTIPLE HEAT PUMP WATER HEATERS INSTALLATION DIMENSIONS...
  • Page 34 MULTIPLE INSTALLATIONS MANIFOLD ARRANGEMENT Hot Manifold Assembly Manifold Arrangement - Multiple Installation Cold Manifold Assembly Heat Pump Water Heaters Manifold Arrangement - Multiple Installation Heat Pump Water Heaters...
  • Page 35: Commissioning

    COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. Open all of the hot water taps in the house (don‟t forget the shower). Open the cold water isolation valve fully to the water heater.
  • Page 36: Draining The Water Heater

    DRAINING THE WATER HEATER To drain the water heater: “To Turn Off The Water Heater” Turn off the water heater (refer to on page 35). Close all hot water taps. Operate the relief valve release lever - do not let the lever snap back or you will damage the valve seat. Operating the lever will release the pressure in the water heater.
  • Page 37 This page is intentionally blank.
  • Page 38 This page is intentionally blank.
  • Page 39: Warranty

    Rheem Accredited Service WARRANTY EXCLUSIONS 1. REPAIR AND REPLACEMENT WORK WILL BE CARRIED OUT AS SET OUT IN THE RHEEM WATER HEATER WARRANTY ABOVE HOWEVER THE FOLLOWING EXCLUSIONS MAY CAUSE THE WATER HEATER WARRANTY TO BECOME VOID AND MAY INCUR A SERVICE CHARGE AND / OR COST OF PARTS.
  • Page 40 WARRANTY – HEAT PUMP WATER HEATER MODEL 551310 Rheem will repair or replace, at Rheem’s sole discretion and subject to the warranty conditions and exclusions, any component, the storage tank or the heat pump module which fails within the warranty period below.