Air Louvre Removal: Using a Phillips head screw driver, remove the six (6) screws from each of the
3.
two air louvres (twelve (12) screws in total).
Remove the louvres from the heat pump module.
Electrical Cover: Remove the mounting screw from the side of the electrical cover.
4.
Gently remove the cover.
The electrical cover needs to be handled gently so as not to damage the electronic controls located
behind the electrical cover.
Step 4
remove electrical cover
5.
Lifting Bars: Insert the two (2) lifting bars into the slots at the front of the heat pump module chassis
and carefully push through to engage the slots at the rear.
Take care not to catch any of the wiring or hoses in the heat pump module.
Leave sufficient overhang at either end to enable a firm and safe grip for lifting the heat pump module
onto the top of the storage tank.
Steps 3 and 5
remove louvres and insert lifting bars into the slots provided
23
HEAT PUMP AND TANK ASSEMBLY