Technical Specifications
Humidity
Humidity
Humidity
Humidity
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Temperature
Temperature
Temperature
Temperature
Heat Dissipation
Heat Dissipation
Heat Dissipation
Heat Dissipation
Tower
Tower
Tower
Tower
H9A10/H9A15 Cabinets
H9A10/H9A15 Cabinets
H9A10/H9A15 Cabinets
H9A10/H9A15 Cabinets
Air Flow and Quality
Air Flow and Quality
Air Flow and Quality
Air Flow and Quality
Altitude
Altitude
Altitude
Altitude
(unpressurized)
Acoustics
Acoustics
Acoustics
Acoustics (Declared values per ISO 9296 and ISO 7779)
Acoustics
Acoustics
Acoustics
Acoustics
Idle
Idle
Idle
Idle
Operating
Operating
Operating
Operating
Vibration
Vibration
Vibration
Vibration
Shock
Shock
Shock
Shock
Electrical (Power supplies are universal, PFC, auto ranging, 100/240 VAC)
Electrical
Electrical
Electrical
Nominal Voltage
Nominal Voltage
Nominal Voltage
Nominal Voltage (VAC)
Voltage Range (VAC)
Voltage Range
Voltage Range
Voltage Range
(temporary condition)
Power Source Phase
Power Source Phase
Power Source Phase
Power Source Phase
Nominal Frequency (Hz)
Nominal Frequency
Nominal Frequency
Nominal Frequency
Frequency Range (Hz)
Frequency Range
Frequency Range
Frequency Range
RMS Current
RMS Current
RMS Current
RMS Current
Pedestal and Rackmount
Pedestal and Rackmount
Pedestal and Rackmount
Pedestal and Rackmount
Single power cord
Maximum VA
M-Series Cabinet (Configuration dependent)
M-Series Cabinet
M-Series Cabinet
M-Series Cabinet
Non-operating
Storage (60 days)
Rate of change
NOTE: Maximum operating temperature at sea level; reduce by 1.8° F (1° C)
NOTE:
NOTE:
NOTE:
for each 600m (2,000 ft) above sea level.
Operating
Non-operating
Storage (60 days)
Operating
Non-operating
Storage (60 days)
Nominal
550W, 1,878 BTU/hr
Configuration dependent
Intake location
Exhaust location
Particle size
Concentration
Operating
Non-operating
NOTE:
NOTE: Higher altitudes are possible if maximum operating temperature is
NOTE:
NOTE:
reduced (see Temperature); other restrictions may apply such as maximum
permissible altitude for hard drives.
LWAd3B
6.3
6.4
NOTE:
NOTE:
NOTE:
NOTE: Current values for specific configurations are available from HP, note
that 1 B = 10 dBA.
Operating
Operating
100
90 to 100
Single
50/60
49-63
6.3A
630
DA - 11432
Worldwide — Version 21 — May 7, 2007
HP AlphaServer DS25 HP AlphaStation DS25
HP AlphaServer DS25 HP AlphaStation DS25
HP AlphaServer DS25 HP AlphaStation DS25
HP AlphaServer DS25 HP AlphaStation DS25
41° to 122° F (5° to 50° C)
–40° to –151° F (–40 to –66° C)
20° F/hr (11° C/hr)
20% to 90%, non-condensing
10% to 90%, non-condensing
10% to 95%
82° F (28° C)
90° F (32° C)
115° F (46° C)
Maximum
780W, 2,664 BTU/hr
Front
Rear Tower, Pedestal, Rack; Rear/top
H9A10/H9A15
N/A
N/A
10,000 ft (3,037 m)
40,000 ft (12,192 m)
LnAm5dBA (bystander position)
45
46
10 to 500 Hz .1 G peak
10G 11ms half-sine (pedestal)
5G 11ms half-sine (rack)
120
110 to 128
Single
50/60
49-63
5.3A
640
120
200 to 240
180-250
Single
50/60
49-63
3.0
690
220-240