Make Electrical Connection; Install Duct Covers - KitchenAid ISLAND CANOPY Installation Instructions And Use & Care Manual

36" and 42" (91.4 cm and 106.7 cm) island canopy range hood
Hide thumbs Also See for ISLAND CANOPY:
Table of Contents

Advertisement

Available languages

Available languages

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved
A. Knockout
B. Terminal box cover
4. Run home power supply cable through strain relief, into
terminal box.
A
C
D
E
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
8
" strain relief.
A
B
B
F
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
5. Use UL listed wire connectors and connect black wires (C)
together.
6. Use UL listed wire connectors and connect white wires (E)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.

Install Duct Covers

1. Attach the vertical duct cover supports using 4 - 4 x 8 mm
screws.
A. Screws
B. Vertical duct cover support
2. Slide upper duct covers into place until springs "click."
A
B
A. Upper duct cover
B. Spring
A