Make Electrical Power Supply Connection To Range Hood - KitchenAid KVWC956JSS0 Installation Instructions And Use & Care Manual

36" (91.4 cm) and 48" (121.9 cm) designer commercial-stylewall-mount canopy range hood
Table of Contents

Advertisement

B
A
A. UL listed or CSA approved
¹⁄₂
" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
7. Go to "Make Electrical Power Supply Connection to Range
Hood" section.
Make Electrical Power Supply Connection to
Range Hood
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Locate terminal box on top of the range hood.
A. Knockout in back of terminal box
B. Top of terminal box
C
D
E
F
G
H
I
F. Blue wires
G. Gray wires
H. Green (or green/yellow) wire
I. 6-wire connector assembly
A
B
A
B
C
D
A. White wires
B. Black wires
C. UL listed wire connectors
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Use UL listed wire connectors and connect white wires (A)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
NOTE: When using an In-line blower motor system, the green (or
green/yellow) ground wire in the conduit from the In-line blower
motor system is to be connected with the green (or bare) wire of
the home power supply cable and with the green/yellow wire (D)
in the terminal box.
5. Connect green (or bare) ground wire from home power supply
to the green/yellow ground wire (D) in terminal box using UL
listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
E
F
D. Green, bare or yellow/green wires
E. Home power supply
F. UL listed or CSA approved
¹⁄₂
" (1.3 cm) strain relief