Sony MDX-C7900 Service Manual page 45

Fm/am minidisc player fm/mw/lw minidisc player
Table of Contents

Advertisement

Pin No.
Pin Name
85
PLL CE
86
HSTX
87
MD2
88
MD1
89
MD0
90
RESET
91
VSS
92
X0
93
X1
94
VCC
95
PW SEL
96
POL MONO
97 to 99
NC
BAND
100
(9K-10K)
101
NC
102
RAMBU
103
NC
104
LCD CE
105
FLASH W
106
REIN0
107
REIN1
LAMP ON
108
(ILL ON)
109
PW ON
110
FM ON
111
TUN ON
NC
112 to 118
119
VSS
120
NC
I/O
O
PLL serial chip enable output to the FM/AM PLL (IC100)
I
Hardware standby input terminal Not used (open)
I
Mode selection input terminal (fixed at "L")
I
Mode selection input terminal (fixed at "H")
I
Mode selection input terminal (fixed at "H")
System reset signal input from the reset signal generator (IC801) and reset switch (S900)
I
"L" is input for several 100 msec after power on, then it changes to "H"
Ground terminal
I
Main system clock input terminal (3.68 MHz)
O
Main system clock output terminal (3.68 MHz)
Power supply terminal (+5V)
I
Power select switch (S700) input terminal "L": on (operation mode), "H": off (halt mode)
I
Polar monaural detection signal input terminal Not used (open)
O
Not used (open)
Frequency select switch (S701) input terminal "H": MW 9k step/FM 50k step, "L": MW10k
I
step/FM 200k step Used for the E model only
O
Not used (open)
Internal RAM reset detection signal input from the RN5VD23AA (IC802)
I
Input terminal to check that RAM data are not destroyed due to low voltage
This checking is made within 100 msec after reset
O
Not used (open)
O
Chip enable output to the liquid crystal display driver (IC801)
I
Fixed at "H" in this set
I
Rotary encoder (EN801) input for volume/bass/treble/balance/fader control
I
Rotary encoder (EN801) input for volume/bass/treble/balance/fader control
Power supply on/off control signal output terminal at the illumination and liquid crystal display
driver (IC801) "H": power on
O
At power select switch (S700) on mode: "H" output at the accessory on
At power select switch (S700) off mode: "H" output at the power on
O
Main system power supply on/off control signal output to the BA3918 (IC800) "H": power on
O
FM system power supply on/off control signal output to the BA3918 (IC800) "H": FM on
O
Tuner system power supply on/off control signal output to the BA3918 (IC800) "H": tuner on
O
Not used (open)
Ground terminal
O
Not used (open)
Function