MINIMUM CLEARANCES TO COMBUSTIBLES: EDVI25, EDVI30 & EDVI35
These appliances can be installed in most residential
fi replace confi gurations. If installed close to an adjacent
wall, ensure that the minimum clearances to combustible
surfaces are maintained. A local building inspector should
review your plans prior to installation.
Refer to Figures 3, 4a, 4b and 5 for Clearances to Combus-
Minimum clearances include spacers/standoffs or
tibles.
surfaces to combustible construction.
Notes for Table 5:
*
This includes any projections such as shelves, window
sills, mantels, spacers/standoffs or surfaces to com-
bustible construction etc. above the appliance. Paint or
lacquer used to fi nish the mantel must be heat resis-
tant in order to avoid discoloration.
** If hearth is elevated, subtract 1 inch of hearth
extension required for every 2 inches of height (see
Figure 6).
Clearances
Side
A
Wall
Figure 3
Mantel Clearance, Models: EDVI30 &
EDVI35: The mantel should be located
in the shaded area (light gray) shown
below.
D
18"
17"
16"
15"
C
14"
0
12
10
8
6
4
11
9
7
5
Top of Insert
Side View
(see "C" on Fig. 3)
Figure 4a
Mantel
G
Hearth Protection
Mantel Clearance, Model: EDVI25: The
mantel should be located in the shaded
area (light gray) shown below.
15 1/2"
13"
11"
C
8 1/2"
0
12"
2
0
3
1
Side View
Figure 4b
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Clearances to Combustibles
A
Side Wall
B Ceiling or Alcove Height
64" (1626 mm)
C * Mantel Height
See Fig. 3 & 4b
D* Mantel Projection from Wall
E
Clearance to Floor
F** Hearth Protection
**16" (406 mm)
(from Fireplace Face)
G
Hearth Protection Width
44" (1118 mm)
45" (1143 mm)
H
Alcove Width
I
Alcove Depth
36" (914 mm)
Table 5
Alcove Minimum Width: The specifi ed minimum width of the
alcove cannot be reduced with the use of wall protection.
Ceiling (or)
Alcove Height
C
Top of Insert
B
I
E
Figure 5
D
0
8"
5"
1"
Top of Insert louver
(see "C" on Fig. 3)
Inches (millimeters)
EDVI25
EDVI30
8" (203 mm)
8" (203 mm)
64" (1626 mm)
See Fig. 3 & 4a
See Fig. 4b
See Fig. 4a
0" (0 mm)
0" (0 mm)
**16" (406 mm) **16" (406 mm)
49" (1245 mm)
50" (1270 mm)
36" (914 mm)
Top View Alcove
Fireplace
Insert
Hearth
H
Hearth Protection: For every 2" of hearth height,
subtract 1" of hearth extension required.
F
Existing Fireplace Hearth
16"
15"
14"
13 1/2"
At 7" hearth height, no hearth extension is required
Figure 6
Min.
EDVI35
Max.
8" (203 mm)
Min.
64" (1626 mm)
Min.
See Fig. 3 & 4a
Min.
See Fig. 4a
MAX.
0" (0 mm)
Min.
Min.
48" (1219 mm)
Min.
49" (1245 mm)
Min.
36" (914 mm)
MAX.
Side View
of Insert
2"
4"
6"
7"