Lennox Hearth Products Elite EDVI25 Installation Instructions Manual page 18

Elite series direct-vent gas fireplace heater inserts
Hide thumbs Also See for Elite EDVI25:
Table of Contents

Advertisement

SAFETY / LISTING LABEL - MODEL: EDVI25
18
MODEL NO.
MANUFACTURED AT:
FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL
ALTITUDE
MIN. GAS SUPPLY PRESS ("WC)
PRESS MIN. D'ALIMENTATION (" CE)
MANIFOLD PRESSURE ("WC)
PRESSION CE TUBULURE ("CE)
MANUFACTURER'S RECOMMENDED ORIFICE SIZE
DIMENSION DE L'INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTU/HR)
ENTREE MAX
MIN INPUT (BTU/HR)
ENTREE MIN
ELECTRICAL RATING/EXI GENCES ELECTRIQUES:
MINIMUM
CLEARANCES TO
CEILING (FROM BOTTOM OF UNIT)
COMBUSTIBLE
MANTEL FROM TOP OF UNIT
MATERIAL
M ANTEL
DEGAGEMENT
MINIMUM DE
PLAFOND (DU BAS DE L'APPAREIL)
MATERIAUX
COMBUSTIBLES
MANTEAU DU DESSUS DE L'APPAREIL
PROFONDEUR DU MANTEAU
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL. FOR INSTALLATION
IN SOLID FUEL FIREPLACES. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE
WITH AIR FILTERS.
FOYER AU GAZ CHAUFFANT AVEC EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
COMBUSTIBLE SOLIDE. DOIT ETRE INSTALLE DANS UNE CHEMINEE EXISTANTE QUI
BRULE LE COMBUSTIBLE SOLIDE. NE PAS UTILISER DE FILTRE A AIR AVEC CE FOYER AU
GAZ A EVACUATION.
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N'UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L' APPAREIL.
Do not operate the appliance with glass removed, cracked or broken.
"CAUTION:
Replacement of panel should be done by a licensed or qualified service person."
"This appliance is equipped at the factory for use with natural gas only. Units using
propane must be field converted using the LP conversion kit, Cat. No. H1576.
FINAL INSPECTION BY:
ANSI Z21.88-2002
CSA 2.33-2002
CAN/CGA 2.17-M91
VENTED GAS FIREPLACE HEATER
FOYERA AU GAZ CHAUFFANT AVEC EVACUATION
SERIAL NUMBER/NOMBRE DE SERIE
XXX XXX
IIIIIIIIIIIIIIIIIIII
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
EDVI25
Lynwood, CA
0-4500 FT/PI
(0-1370M)
4.5"
3.5"
#41
25,000
17,000
-UNIT/APPAREIL: MILIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
SIDEWALL
FLOOR
DEPTH
(MAX)
MUR ADJACENTS
PLANCHER
(MAX)
P/N 9-1467C
XXX
P/N 9-1467C
8"
0"
64"
15.5"
12"
203mm
0mm
1626mm
394mm
305mm

Hide quick links: