DSC PC1616; PC1832; PC1864 Installation Manual page 53

Powerseries
Hide thumbs Also See for PC1616; PC1832; PC1864:
Table of Contents

Advertisement

Appendix A: Reporting Codes
The following tables contain Contact ID and Automatic SIA format reporting codes. For more information on reporting code formats and notes
about individual reporting codes, (see Section 5.6 Communicator Programming PWS Sect 6).
Contact ID
The first digit (in parentheses) will automatically be sent by the control. The second two digits are programmed to indicate specific information
about the signal. For example, if zone 1 is an entry/exit point, you could program the event code as [34]. The central station would receive the
following:
*BURG - ENTRY/EXIT - 1 where the "1" indicates which zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard - October
1997. This format will send the Account Code along with its data transmission. The transmission will look similar to the following at the receiver:
N Ri01
N
=
Ri01
=
BA
=
01
=
NOTE: A system event will use the Area Identifier Ri00.
Section #
Reporting Code
[320]-[323]
Zone Alarms
[324]-[327]
Zone Restorals
[328]
Duress Alarm
[328]
Opening After Alarm
[328]
Recent Closing
[328]
Zone Expander Supervisory
Alarm/Rest.
[328]
Cross Zone (Police Code)
Alarm
[328]
Burglary Not Verified
[328]
Alarm Cancelled
[329]
[F] Key Alarm/Rest.
[329]
[A] Key Alarm/Rest.
[329]
[P] Key Alarm/Rest.
[329]
Aux Input Alarm/Rest
[330]-[337]
Zone Tamper/Restoral
[338]
General System Tamper/
Rest.
[338]
Keypad Lockout
[339-341]
Closings
[341]
Partial Closing
[341]
Special Closing
[341]
Late to Close
[341]
Exit Fault
[342-344]
Openings
[344]
Auto-arm Cancellation
[344]
Special Opening
[345]-[346]
Battery Trouble/Rest.
[345]-[346]
AC Line Trouble/Rest.
[345]-[346]
Bell Circuit Trouble/Rest.
[345]-[346]
Fire Trouble/Rest.
BA 01
New Event
Partition /Area Identifier
Burglary Alarm
Zone 1
Code Sent When...
Zone goes into alarm
Alarm condition has been restored
Duress code entered at keypad
System disarmed with alarm in memory
Alarm occurs within two minutes of system arming
Panel loses/restores supervisory transmission over the Keybus
from zone expansion modules, or keypads with zone inputs
Two zones on the same partition go into alarm during any given
armed-to-armed period (incl. 24Hr zones)
Keypad fire alarm (alarm and restore rep. codes sent together)
Keypad auxiliary alarm (alarm and restore rep. codes sent
together)
Keypad panic alarm (alarm and restore rep. codes sent together) A/R
Option#23/24: a panic button wired to PGM 2 is pressed/access
code is entered
Option #04: a 2-wire smoke detector wired to PGM 2 goes into
alarm/alarm is cleared.
Zone is tampered / tamper condition restored
Enrolled module with tamper inputs has a tamper alarm/all mod-
ule tampers restored
Maximum number of incorrect access codes has been entered at
a keypad
System armed (user 01-34, 40-42 indicated)
One or more zones bypassed when system armed
Closing (arming) using one of the following methods: quick arm,
auto arm, keyswitch, function key, maintenance code, DLS soft-
ware, wireless key
Whenever the Auto-arm prealert sounds (if the Late to Close
option is enabled)
System disarmed (user 01-34, 40-42 indicated)
Auto-arm cancelled
Opening (disarming) using one of the following methods: key-
switch, maintenance code, DLS software, wireless key
PC1616/PC1832/PC1864 battery is low/battery restored
AC power to control panel is disconnected or interrupted/AC
power restored (Both codes follow AC Failure Comm. Delay.)
Open or short circuit detected across bell terminals/bell circuit
restored
Trouble occurs/restores on a fire zone
Appendix A: Reporting Codes
Automatic
Dialer
Contact ID
Direction*
Rep Codes**
Codes
A/R
See Table 3
See Table 3
A/R
A/R
(1) 21
HA-00
A/R
(4) 58
OR-UU
A/R
(4) 59
CR-00
A/R
(1) 43
UA-00/UH-00
A/R
(1) 39
BM-00/BV-00
A/R
(3) 78
BG-00
A/R
(4) A6
BC-00
A/R
(1) 1A
FA-00/FH-00
A/R
(1) AA
MA-00/MH-00
(1) 2A
PA-00/PH-00
A/R
(1) 4A
UA-99/UH-99
A/R
(1) 11
FA-99/FH-99
T/R
(3) 83
TA-ZZ/TR-ZZ
T/R
(1) 45
ES-00/EJ-00
T/R
(4) 61
JA-00
O/C
(4) A1
CL-UU
O/C
(4) 56
CG-ZZ
O/C
(4) AA
CL-00
O/C
(4) 54
CI-00
O/C
(3) 74
EE-00
O/C
(4) A1
OP-UU
O/C
(4) 55
CI-00
O/C
(4) AA
OP-00
MA/R
(3) A2
YT-00/YR-00
MA/R
(3) A1
AT-00/AR-00
MA/R
(3) 21
YA-99/YH-99
MA/R
(3) 73
FT-99/FJ-99
SIA Auto

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1616Powerseries pc1832Powerseries pc1864