Something Not Working; Instructions For The Installer; Engineerstechnical Data - Zanussi ZGF 7899 Instruction Booklet

Table of Contents

Advertisement

Something Not Working?

If the appliance is not working correctly, please carry out the following checks before contacting your local
Service Centre.
SYMPTOM
There is no spark when lighting the gas
The gas ring burns unevenly
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.

Instructions for the Installer

Engineers technical data
OVERALL DIMENSIONS
Width:
680 mm
Depth:
510 mm
Height:
85 mm
CUT OUT DIMENSIONS
Width:
560 mm
Depth:
480 mm
Thickness: 30 mm
Burner
Auxiliary
Semi-rapid
Rapid
Triple crown
(*) 1 mbar = 10 mm. water coloumn
Nominal Power LPG (Butane "A")
kW
kCal/h
Nozzle
0,95
814
50
1,60
1368
65
2,45
2095
80
3,60
3080
98
SOLUTION
Check that the unit is plugged in and the
electrical supply is switched on
Check the mains fuse has not blown
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Check the main jet is not blocked and the
burner crown is clear of food particles.
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Supply Connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand
corner
Electric:
230-V 50 Hz supply, 3 core flexible cable with
non rewireable plug.
Appliance Gas supply: LPG 30 mbar
Appliance Class: 3
Appliance category: I 3
Diameter
Tap. By-Pass
g/h
75
28
126
35
193
45
284
56
Feeding
Pressure
mbar (*)
30
7

Advertisement