Operation - Zanussi ZGF 642 CTN Instruction Booklet

Gas hobs
Table of Contents

Advertisement

Operation

Hob burners
To light a burner:
turn the relevant control knob anticlockwise to the
maximum position, then push it down to ignite the
burner.
upon ignition, keep the knob pushed down about 5
seconds. This will allow the "thermocouple" (see
diagram, lett. D) to be heated and the safety device to
be switched off, otherwise the gas supply would be
interrupted.
then, check the flame is regular and adjust it as
required.
If you cannot light the flame even after several attempts,
check the "cap" and "crown" (see diagram, lett. A, B) are
in the correct position.
To put the flame out, turn the knob to the symbol .
When switching on the mains, after
installation or a power cut, it is quite normal
for the spark generator to be activated
automatically.
To ensure maximum burner efficiency, you should only
use pots and pans with a flat bottom fitting the size of
the burner used (see table).
Burner
Large (rapid)
Medium (semi-rapid)
Small (auxiliary)
If you use a saucepan which is smaller than
the recommended size, the flame will spread
beyond the bottom of the vessel, causing the
handle to overheat.
Take care when frying food in hot oil or fat,
as the overheated splashes could easily
ignite.
As soon as a liquid starts boiling, turn down the
flame so that it will barely keep the liquid simmering.
If the control knobs become difficult to turn, please
contact your local Service Force Centre.
4
minimum
maximum
diameter
diameter
180 mm
260 mm
120 mm
220 mm
80 mm
160 mm
A - Burner cap
B - Burner crown
C - Ignition electrode
D - Thermocouple