Burner And Nozzle Characteristics Table - Smeg SSA60GGX9 Instructions For Use Manual

Gas/electric cookers
Table of Contents

Advertisement

11.5.2Adjusting the hob burner minimum setting for LPG
In order to adjust the minimum setting with LPG, the screw at the side of the tap rod must be tightened
clockwise all the way.
11.5.3Adjusting the gas oven burner minimum setting
1 Light the oven burner and keep it at the maximum for 10/15 minutes.
2 Then turn the knob to the minimum temperature.
3 Extract the gas tap knob and turn the adjustment screw next to the tap rod
(depending on the model) until the correct minimum flame is achieved.
4 Refit the knob and verify that the burner flame is stable (when turning the
knob rapidly from the maximum to the minimum position the flame must not
go out). This procedure must be carried out while the door is closed.
5 (Only for adjustment different from LPG) Open and close the door, if the flame
goes out the minimum must be increased.
If using LPG, the adjustment screw must be tightened to end of stroke. If using city gas or natural gas,
simply unscrew the adjustment screw by a few turns.

11.6 Burner and nozzle characteristics table

Burner
Auxiliary
Semi-rapid
Rapid
Ultra-rapid
Oven
Grill
Burner
Auxiliary
Semi-rapid
Rapid
Ultra-rapid
Oven
Grill
34
Instructions for the installer
Rated heating
capacity
(kW)
Nozzle
diameter
(1/100 mm)
1.05
1.8
3.0
3.5
2.6
2.4
Rated heating
capacity
(kW)
Nozzle
diameter
(1/100 mm)
1.05
1.8
3.0
3.5
2.6
2.4
LPG GAS - G30/G31 28-30/37 mbar
Reduced
capacity
(W)
50
400
65
500
85
800
94
1600
76
900
76
-
NATURAL GAS - G20 20 mbar
Prechamber
(printed on
nozzle)
72
(X)
97
(Z)
115
(Y)
133
(S)
120
-
120
-
Capacity
Capacity
(g/h G30)
(g/h G31)
76
75
131
129
218
214
255
250
189
186
175
171
Reduced capacity
(W)
400
500
800
1600
900
-
9 1 4 7 7 5 3 7 3 / A

Hide quick links:

Advertisement

Table of Contents
loading