12" min.
3" min.
3" min.
PL vent manufacturer's
fi re stop s pa ce r an d
support
Fig. 18
#7 Installing through the ceiling vent
Thr ough the c eiling vent, f ollow PL vent
manufacturers recommendations when using wall and
ceiling pass through.
Fig. 20
12
PC 45 Corn/Pellet Stove
Venting
Storm collar
Flashing
3" min.
No insulation or
other combustible
ma te ri al s
are
allowed within 3"
of the PL ve nt
pipe.
(See Page 6 for
corner installation
clearances)
Minimum flue vent configuration
It is rec ommended that
outside air be installed with this
venting configuration.
Fig. 19
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
INSTALL VENT AT CLEARANCES SPECIFIED
BY THE MANUFACTURER
WARNING
DO NOT INSTALL IN SLEEPING ROOM
CAUTION
THE STRU CTURAL INTEGRITY OF TH E
MOBILE HOME FLOOR, WALL, AND CEILING/
ROOF MUST BE MAINTAINED.
CAUTION
THE STOVE IS HOT WHILE IN OPERATION.
KEEP
C HILD REN,
FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.
C LOTH IN G
AN D